A202 Mid-Rise Fires (09/01/2016) Flashcards

1
Q

[A202 Mid-Rise Fires]

Mid-Rise buildings are ___ stories or more, yet no greater than ____ feet high.

A

4 stories 75 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

[A202 Mid-Rise Fires]

Mid-rise buildings will often be 5-6 stories in height but can be as tall as ___ stories:

A

8 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

[A202 Mid-Rise Fires]

Modern mid-rises are being built with what type of occupancy?

A

Mixed-use occupancy

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

[A202 Mid-Rise Fires]

This SOG has been designed to be flexible, allowing for a variety of firefighting tactics to be supported with extra consideration given to:

A

The difficulty in placing the aerial apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A Mid-rise alarm complement will consist of: [A202 Mid-Rise Fires]

A
  • 4 Engines
  • 3 Ladders
  • 1 Rescue
  • 2 Batt chiefs
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

[A202 Mid-Rise Fires]

At Mid-Rise fires, the command post should be placed:

A

In the most advantageous position to manage the incident

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

[A202 Mid-Rise Fires]

The 2nd arriving Batt chief should respond to the command post and then one chief will become IC and the other will be:

A

Fire Floor Division Supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

[A202 Mid-Rise Fires]

First arriving engine will assume:

A

Fire attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

[A202 Mid-Rise Fires]

Besides the standpipe system, other options of fighting the fire include:

A

Blitz attack or short attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

[A202 Mid-Rise Fires]

The driver of the first in engine will do what?

A

Stay with the engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

[A202 Mid-Rise Fires]

The driver of the first in engine will become part of the:

A

Water Supply Group

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

[A202 Mid-Rise Fires]

The 2nd arriving engine will assume:

A

Fire attack 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

[A202 Mid-Rise Fires]

If fire attack 1 does not need assistance with fire attack, what should fire attack 2 do?

A

Report to command that they are available to be assigned as the backup team

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

[A202 Mid-Rise Fires]

The driver of the 2nd in engine should:

A

Stay with the engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

[A202 Mid-Rise Fires]

The driver of the 2nd in engine will become part of the:

A

Water Supply group

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

[A202 Mid-Rise Fires]

The 3rd in engine will:

A

Standby near a hydrant and assume Water Supply Group Supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

[A202 Mid-Rise Fires]

If a fire attack method other than supplying the standpipe is utilized, consideration should be given to:

A

Supplying the FDC for the sprinkler system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

[A202 Mid-Rise Fires]

4th in engine will:

A

Standby at a hydrant and await assignment from command

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

[A202 Mid-Rise Fires]

First in aerial/rescue will:

A

Assume inside truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

[A202 Mid-Rise Fires]

Who will serve as the Fire Floor Division Supervisor before the arrival of the BC?

A

The 1st in aerial/rescue officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

[A202 Mid-Rise Fires]

How should 1st in aerial position?

A

For aerial ladder use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

[A202 Mid-Rise Fires]

1st in aerial/rescue driver will:

A

Remain with the apparatus

23
Q

[A202 Mid-Rise Fires]

1st in aerial/rescue driver will become part of:

A

Outside division

24
Q

[A202 Mid-Rise Fires]

2nd in aerial/rescue will assume:

A

Evacuation Group

25
# [A202 Mid-Rise Fires] What should be done if Evacuation Group decides to use the inside of the building to house evacuees?
Air monitoring
26
# [A202 Mid-Rise Fires] If an aerial is 2nd in, it should be positioned for:
Aerial ladder use
27
# [A202 Mid-Rise Fires] The driver of the 2nd in aerial/rescue should:
Stay with apparatus
28
# [A202 Mid-Rise Fires] The driver of the 2nd in aerial/rescue will become part of:
Outside Division
29
# [A202 Mid-Rise Fires] 3rd arriving aerial/rescue will assume:
Ventilation Group
30
# [A202 Mid-Rise Fires] What is the first priority of Ventilation Group?
Determine if any assistance is needed by interior crews to coordinate ventilation with fire attack
31
# [A202 Mid-Rise Fires] Proper flow paths should be established to move products of combustion out of the structure and away from crews entering for fire attack. How can this best be accomplished?
The use of PPV fans
32
# [A202 Mid-Rise Fires] What is the 2nd priority of Ventilation Group?
Use PPV fans to pressurize enclosed stairwells
33
# [A202 Mid-Rise Fires] 4th in aerial/rescue will assume:
Outside Truck
34
# [A202 Mid-Rise Fires] Who will assume outside supervisor?
4th in aerial/rescue officer
35
# [A202 Mid-Rise Fires] Outside division will be responsible for these 3 things:
1. Aerial ladder placement 2. Management of the occupants/bystanders outside the building 3. Locating and silencing the fire alarm when requested
36
# [A202 Mid-Rise Fires] EMS should be assigned this upon arrival:
Medical Group
37
# [A202 Mid-Rise Fires] What other (3) tactical assignments should command fill before 2nd alarm?
1. RIC 2. Backup team 3. Salvage Group
38
# [A202 Mid-Rise Fires] Should a mid-rise escalate to 2nd alarm, these 3 things should be established:
1. Staging 2. Rehab 3. Base
39
# [A202 Mid-Rise Fires] All aerial apparatus should position for:
Aerial ladder use
40
# [A202 Mid-Rise Fires] In defensive mode, all units will respond and begin exterior operations in accordance with A101. The only deviation of assignments should be:
2nd in aerial/rescue. They should assume Evacuation Group
41
# [A202 Mid-Rise Fires] In investigative mode, all units will respond in accordance with A101. The only deviation of assignments should be:
2nd in aerial/rescue. They should assume Evacuation Group
42
# [A202 Mid-Rise Fires] On a Light-Box alarm in mid-rise, the 2nd arriving pumping apparatus may do these things:
Assist with incident needs outside the structure Manage evacuating occupants Silence the alarm Shut down fire pump
43
# [A202 Mid-Rise Fires] Building construction features of mid-rise buildings are usually based on:
Occupancy use
44
# [A202 Mid-Rise Fires] What is unique regarding the wood frame exterior walls of a mid-rise?
Not always load bearing. Check for extension in these areas
45
# [A202 Mid-Rise Fires] The placement of these apparatus will have the highest priority:
Aerial ladders
46
# [A202 Mid-Rise Fires] These 4 locations should be sized up at mid-rise fires:
1. Exterior 2. Interior 3. Fire Floor 4. Fire room
47
# [A202 Mid-Rise Fires] The exterior mid-rise sizeup should contain these 2 things:
1. Number of stories 2. If fire or smoke is showing
48
# [A202 Mid-Rise Fires] The interior mid-rise sizeup should contain these 2 things:
1. If fire alarm is sounding 2. If smoke is in the stairwell
49
# [A202 Mid-Rise Fires] The Fire Floor mid-rise sizeup should contain these 3 things:
1. Confirmation of floor number 2. Fire/smoke conditions on that floor 3. Actions being taken
50
# [A202 Mid-Rise Fires] The Fire room mid-rise sizeup should contain these 2 things:
1. Room/apartment number 2. Actions taken
51
# [A202 Mid-Rise Fires] Unlike high-rises, most mid-rises dont have a:
Fire Control Room
52
# [A202 Mid-Rise Fires] Where will the building keys be located at a mid-rise?
Knox Box
53
# [A202 Mid-Rise Fires] When utilizing a standpipe for fire attack in a mid-rise, what must be done first before fire attack can begin?
The FDC must be supplied by an engine with a sustainable water supply