A4a Ultra Radiac Personal Radiation Monitor Flashcards
Ultra Radiac Detects ?
Gamma and X-ray Radiation
-rate and dose
UltraRadiac will be turned on when?
Officers leave quarters
-secured to HT with Ultra Radia retention strap–CONTINUOUSLY
When are the doses cleared? For Officers
BEGINNING OF EACH TOUR
Firefighters Ultra Radiac are stored in?
YELLOW PELICAN CASE
Secured to FF by?
- Retention Strap - HT
- Ultra Radia Case- BUNKER COAT
FF’s are required to wear and have their Ultra Radiacs turned on, operationally tested and doses cleared prior to…?
OPERATING AT RADIOLOGICAL INCIDENTS and EMERGENCIES or when ordered by INCIDENT COMMANDER
Rate/Dose Range?
- Rate Range- 1.0 uR/hr to 999mR/hr to 500R/hr
- Dose Range- 0.1 uR to 999mR to 999R
Note: 1,000,000 uR= 1000mR=IR
Clearing Accumulated Dose?
- Press DOSE- see accumulated dose
- Press and hold DOSE + CLR/TEST KEYS
- display will flash and then clear accumulated dose
- return to Rate mode- PRESS RATE KEY
Note:accumulated dose is NOT cleared when Ultra Radiac is turned off
Source Finder Mode…
- locate and isolated source using AUDIBLE SOURCE
- unit will start clicking near radioactive material
- closer to radiation/click faster
- aim TOP OF UNIT AT the suspected source of radiation
Enable Source Finder Mode:
-press and hold RATE key until display changes to flashing “I”/then release Rate key
Exit Source Finder Mode
–press and hold the RATE key/display flashing “0”/release Rate Key
Alarms for Ultra Radiac?
LOW- 2 mR/hr- 5 R
High- 50 R/hr- 12 R
At a Radiological incident or emergency,Do NOT turn Green Light and the Alarm indicator , which will clear the accumulated Dose until?
DOSE IS RECORDED or when ORDERED BY IC
Batteries
- blinking b displayed , unit stopped functioning and batteries need to be replaced
- blinking BAT is seen in top left corner , batteries have 10 hours or less of useful life…replace
- display is blank, batteries are dead, replace
Batteries should be stored?
- in Firefighter UltraRadiac Container (yellow pelican case) AND OUTSIDE INSTRUMENTS
- minimum of 8 batteries for each Ultra Radiac stored within the case
Return OOS Ultra Radiacs to?
HAZMAT OPS
DO NOT permanently mark ULTRARADIACS OR CASES with any type of unit designation