TOOLS 7/HAND HELD NOZZLES Flashcards
1
Q
SOLID STREA TIPS are generally stacked..
A
MST-MAIN SOLID STREAM TIP-first tip of stack, attached directly to SHUT OFF (SO)
OST-outer solid stream tip-attachment to MST-further reduce bore diameter …1/2” tip is a OST
2
Q
ANY COMBINATION SS/FOG should remain in…
A
STRAIGHT STREAM POSITION WHEN STORED ON HOSE BED (prevents damage to baffle)
3
Q
A LIGHT COAT OF OIL shall be put on all couplings and moving parts AFTER CLEANING..
A
Excessive force should not be used to tighten nozzle components or couplings
- neither the control handles or SO’S and FN’S , nor the shut off valve itself shall be used for the purposes of holding or clamping nozzles to holder
- NOZZLES should work FREELY
4
Q
CONTROLLING nozzles tested in AUGUST ..
A
- 2 lengths of hose from pumper , sufficient pressure
- shut off’s open and closed several times
- defective nozzles should be RT-4 to Repairs and Transportation unit
new issue or repaired nozzles should bet tested before being placed in service