Akron New Yorker Multiversal T-17 Flashcards
Range of elevation?
90 degrees above
15 degrees below
Safety stoplock and release pin?
prevents lowering elevation below 35 degrees above horizontal…should be pulled BEFOrE reaching 35 degrees
-safety stop at 35 degrees ABOVE
No operation BELOW THE HORIZONTAL shall be attempted unless the unit is…?
secured to Truck mount
-base MUST be used if removed from apparatus truck mount
Horizontal Friction Lock…
hold the Multiversal in a stationary position , if released , permits 180 degree movement horizontally
Stacked tip?
1 1/4”-1 1/2”-2”
(2) 3 inch clapper type swivels for supply
2 members shall remove mulitversal from apparatus and lower to ground
-but ONE member can carry to point of operation
To prevent backward movement of Multiversal Nozzle, it must be secured in position by means of a utility rope in following manner….?
- middle of rope on top of siamese, over ID plate
- bring 2 sides of the rope under siamese and up between 2 inlets
- bring the 2 sides of rope up over siamese and bring each side forward to the large leg of the ground base on each side of the front leg…make half hitch on each of these 2 legs
- bring rest of each rope forward…rope must be taut and ALL SLACK REMOVED
- SAFETY CHAIN should never be relied on
-do not connect hoselines before tying knots
When supplying multiversal…?
TWO LINES is RECOMMENDED (not a must)
- bring them straight back 15 FEET from siamese, parallel to each other, before making turns
- when used in PORTABLE GROUND BASE, unit should not be operated at more than 800 Gallons per minute
Pressures shall not be exceeded:
1 1/4”- 100 PSI
1 1/2” - 70 psi
2”- 50 psi
1075
- GAUGE PROVIDED on MULTIVERSAL can be used
- when supply line feeding mULTIVERSAL ARE LONG, so that communications with ECC may be difficult, insert single gate ONE length from nozzle , a member can be stationed at this gate so that pressures are maintained
After each use, spikes in portable ground base must be inspected,
If the flats on the end of the SPIKES base exceed 1/16” diameter…
spikes MUST be sharpened
Horizontal rotation of nozzle is limited to?
90 degrees in each direction
The Akron New Yorker should never operate in the portable position, unless it is…
secured in the portable ground base, by using prescribed knots
If for any reason units are unable to secure the Multiversal Nozzle in portable ground base or apparatus truck mount, it should be taken OUT OF SERVICE and _________is notified?
Repairs and Transportation Unit
mAXIMUM PRESSURE to which any part of this appliance should be subjected to is ?
200 PSI
-to throughly drain, turn UPSIDE DOWN
-IN PORTABLE POSITION, horizontal rotation is limited to 90 degrees in each direction (180 total)