KO Curtain and EVOLUTION 34 Flashcards
Curtain and ropes tested to ?
T-2
2000 degrees
-survived 50 mph winds and 60 minutes of fire exposure
Dimensions- 8’x 6’
15 foot longs ropes
Testing Showed?
T-2
IMMEDIATE 50% DECREASE in temperatures and significant flame reduction
INCREASE in smoke condition
2 1/2” handline will NOT provide sufficient cooling
(same as Blanket)
Inspect KO CURTAIN?
T-2
WEEKLY MUD/after each use
-inspection will include REMOVING curtain from carrying sleeve and unfurling it
any doubt, placed the curtain OOS
Repacking procedure…
T-2
- place on flat surface-REFLECTIVE stripes UP
- Ropes loosely coiled and clipped together
- rolled from BOTTOM to top, bottom ropes within roll
- ropes are placed 5-10 INCHES from top edge of curtain and roll is completed
- place into carrying case
Under no circumstances should the KO Curtain be DEPLOYED for ?
T-2
Drill purposes
Division has training Curtain for Drill (same as blanket)
-remember- this does not preclude removing curtain from case for inspection
Replacement Curtain- Completion of Ops where curtain has been deployed…
T-2
IC will secure for Safety Battalion
LADDER company OFFICER OF confiscated curtain (not officer that deploy it) will prepare report to Chief Of Operations, detailing use, damage, any other info for future use….COPY TO CHIEF OF FIRE ACADEMY (same as Blanket)
For replacement of KO CURTAIN?
T-2
contact Division(don’t confuse with Blanket)
If KO Curtain damaged in OTHER than Fire Ops…
T-2
Report to Chief Of Ops….replacement from DIVISION (no mention Of copy for chief of fire academy)
Under no circumstances should the KO Curtain be DEPLOYED for ?
T-2
Drill purposes
Division has training Curtain for Drill (same as blanket)
-remember- this does not preclude removing curtain from case for inspection
KO training curtain-delivered by division messenger
- officer will verify condition prior to signing RT-2
- Inspect after drill….any doubt , call tech services ….if placed OOS, prepare an RT-2 AND Arrange for Division to deliver to TECH services
KO CURTAIN shall be deployed for following conditions?
EV-34
a. a window in FIRE APT. has failed and size up indicates wind is blowing the fire into the apartment continuously or intermittently
B. size up indicates that deployment of the KO curtain prior to window failure will prevent a wind driven fire from developing
KO Curtain will ONLY be deployed on orders of the ?
EV-34
INCIDENT COMMANDER….
2ND ARRIVING LADDER company officer will coordinate the deployment once ordered
Prepare KO Curtain for deployment…?
EV-34
remove any window gates, child guards, blinds, curtains or other obstructions
DO NOT remove or break the deployment window unless ABSOLUTELY NECESSARY..intact window provides protection from auto exposure
Prepare KO Curtain for deployment…?
EV-34
remove any window gates, child guards, blinds, curtains or other obstructions
DO NOT remove or break the deployment window unless ABSOLUTELY NECESSARY..intact window provides protection from auto exposure
Deployment FF tools?
EV-34
Curtain, HYDRAM RAM , HALLIGAN
-deploy from apt. above or TWO FLOORS above or from ROOF if fire is on top floor
-PRESSURIZE WATER EXTINGUISHER may be required at the place of deployment /handline may be required for SEVERe auto exposure
Receiving FF tools?
EV34
hydra ram, halligan, HALLIGAN HOOK
-secure lower ropes and coordinate positioning over TARGET WINDOW