Tools 7,11,17,29 Flashcards

1
Q

Does MST tip have threads at its outlet orifice?

A

Yes

because it has to connect the OST 1/2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

T/F Fog stream tip in the straight stream position is hollow?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

T/F Variable flow FT’s, more water is generally flowing in the straight stream position than the fog position?

A

False

more water flows in the fog

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What do u use to clean nozzles?

A

Hot water

solution of soap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Can u use oil on couplings and moving parts?

A

Yes a light coating.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

ID letters and number shall be

placed where on the nozzles?

A

stamped along the coupling along the hub, adjacent to the coupling lug

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Nozzles should be tested in ______?

A

August and when deemed necessary.

PS when testing use 2 lengths of hose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HRN, What size is the diameter pipe?

A

1 1/2

with 2 1/2 shutoff and 1 1/8 mst

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When will HRN be dispatched?

A

Every 10-77

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Who is responsible for HRN?

A

4th due eng

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If 4th engine not equipped with HRN what should the officer do?

A

Officer contacts dispatch to find out the HRN unit on the scene.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What should each engine carry at a hrfpmd?

A

1 length of 2 1/2 PER FF
HRN
standpipe kit with controlling nozzle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How long is HRN?

A

8ft

PS bend of 68 degrees.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

T/F HRZ is permanently attached to nozzle?

A

True

PS the handle has a T shape

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The 1 1/8 MST on the HRZ should be checked when?

A

tip is removable and checked weekly at MUD

and BEFORE use.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The HRN will flow between _________ gpm at

______ psi nozzle pressure.

A

200-225

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

When HRN is in use the spotter

reports results to who?

A

IC and Members OPERATING.

PS Spotter will be in the best position to monitor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

How many companies will it take to put the HRN into operation?

A

2

PS may have to be stretched from 3 floors below engine might have to force door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

T/F HRN to operate u will have o remove child gates,and window bars?

A

True
PS in most cases u do not have to remove the
window.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Who will maintain and initiate HT contact with the spotter?

A

Officer supervising HRN.

21
Q

If multiple rooms are on fire, which room do u start with when using HRN?

A

Start with the window that the wind is blowing into the move downwind of the original fire room.
PS If only 1 room attack seat of fire.

22
Q

HRN, where is the shut off located?

A

1 length of nozzle

PS shut down from there to reposition

23
Q

Repairs and replacement of HRN?

A

Tech Services

24
Q

T/F Male threads always point in the direction of water flow.

A

False

Normally point

25
What size tips are on the Akron NY Multi and what is the PSI.
1 1/4 -100psi 1 1/2- 70psi 2------50psi ACRO 10-75
26
T/F Safety chain for the Akron NY must be used?
False | May be used
27
Akron NY, elevation control handle range in elevation of _____ degrees above and ____ below degrees below horizontal.
90 degrees above | 15 degrees below
28
Akron NY, Safety pin prevents the lowering below____ degrees above the horizontal.
35 degrees PS should be pulled PRIOR to reaching 35 degrees
29
Akron NY, Horizontal friction lock permits _____ degrees to be transversed HORIZONTALLY
180
30
What color is the Akron NY Muti locking plunger | retaining latch assembly?
Bright Orange | PS Most plungers are Orange and should be in line with front leg.
31
Akron NY Multi, the TEE Handle should face which direction?
Tee UP | PS just like golf
32
Akron NY Multi, to secure with the utility rope place the middle of the rope ______ of the siamese and bring 2 sides of the rope under the siamese and up between 2 inlets.
on top | PS half hitch on legs and tie to substantial object which is FORWARD with clove hitch and binder.
33
Akron NY multi. What comes 1st, the knots or the connection of the hose?
Knots 1st hose 2nd PS maintenance conducted quarterly
34
T/F Akron NY multi, u must supply with 2 lines.
False, is recommended | PS bring back for 15 feet before making turns
35
Akron NY Multi should not be operated at more than ____ gallons per minute.
800 gallons | PS use single gate 1 length back just like HRN
36
Akron NY Multi, If the flats on the ends of the spikes exceed _____ in diameter replace or sharpen.
1/16" | PS Repairs and Transport Unit
37
Akron NY Multi, What is the max pressure?
200 psi | PS just like educator
38
TIF carried by Who?
Batt and Ladders
39
Tif can detect as low as ____ppm with its ticking | signal.
5 ppm
40
Is the TIF intrinsically safe?
yes,in methane mixtures only. | PS does not detect CO
41
TIF to turn on, SLIDE the on/off switch?
True
42
Where else would u use the TIF?
gas lines/pipes fuel in marine bilges exhaust in fuel leaks manholes
43
TIF Initial charge is______.
1 day | ps recharges 1/2 to 2/3 of a day
44
TIF, Test proper recharge by turning SENSITIVITY knob left to right the sound will be?
ticking to full siren
45
TIF will last for how long of continuous use?
4 hours
46
TIF in a non contaminated atmosphere will it make any sound?
No sound just the power light.
47
How long does it take the TiF to warm up?
30 seconds | PS it will tick until compound is detected and then it will go into siren mode
48
TIF, for extremely small leaks turn the sensitivity knob to what position?
HI position | PS do the opposite in the other situation
49
TIF repaired by who?
MSU