Natural Gas emergencies & fires Flashcards
Priority order of valve shutdown ?
Appliance, Meter, Head of service(found just INSIDE bld where gas service enters), Exterior gas riser valve(before any exterior meter, Curb valve, Street valve
Mostly methane. Also contains nitrogen, ethane, propane. Ignites at __, colorless/odorless, lighter then air, explosive range _ to _, non-toxic, asphyxiant.
1163 degrees, explosive range 5-15%
How do you shut curb valve ?
1/4 turn clockwise
Some older curb valves require multiple turns to close.
7 1/2 to 15 full turns
FDNY TIC: intrinsically safe. ?
No. FD issued flashlights are
Leaking plastic gas pipe ?
Do not touch or come near a leaking plastic pipe
Dept fans are not intrinsically safe & should not be used to vent gas ? T o F
True
Mjr indoor gas leak: start venting ?
Upper floors & work your way down to the first floor
Sewer man covers can be removed ?
Approval of on scene Chief Officer
Electric manhole covers: removal ?
By FDNY when requested by utility company gas rep & on scene Chief. Prior to removal utility co checks for stray voltage
Round manhole covers should be removed by 2 FF utilizing manhole hooks. Where are they found ?
Battalion vehicle carry two. Do not pull rectangular or square electric manhole covers.
CGI - Tiff carried by ?
Batt & ladder co
MSA altair carried by. ?
ALL non soc supprt ladder companies
DCGI: all SOC, SSL, HMTU. Calibrated to % of gas in air ? T o F
True
DCGI & Altair alarm at ?
10% LEL the Indoor action level & different alarm 20% LEL the outdoor action level. Begin evac at 10% LEL