Tissue Processing (Junqueira) Flashcards

1
Q

Tissues have two interacting components:

A

cells
extracellular matrix (ECM).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

consists of many kinds of macromolecules, most of which form complex structures, such as collagen fibrils.

A

Extracellular Matrix - ECM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

supports the cells and contains the fluid transporting nutrients to the cells, and carrying away their wastes and secretory products.

A

Extracellular Matrix - ECM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Small pieces of tissue are placed in solutions of chemicals that cross-link proteins and inactivate degradative enzymes, which preserve cell and tissue structure.

A

Fixation:l

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The tissue is transferred through a series of increasingly concentrated alcohol solutions, ending in 100%, which removes all water.

A

Dehydration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Alcohol is removed in organic solvents in which both alcohol and paraffin are miscible.

A

Clearing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The tissue is then placed in melted paraffin until it becomes completely infiltrated with this substance.

A

Infiltration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The paraffin-infiltrated tissue is placed in a small mold with melted paraffin and allowed to harden.

A

Embedding

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The resulting paraffin block is trimmed to expose the tissue for sectioning (slicing) on a microtome

A

Trimming

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

is used for sectioning paraffin-embedded tissues for light microscopy

A

microtome

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The trimmed tissue specimen is mounted in the paraffin block holder, and each turn of the drive wheel by the histologist advances the holder a controlled distance, generally from

A

1 to 10 μm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

For TEM, sections less than 1 μm thick are prepared from resin-embedded cells using an _______ with a glass or diamond knife.

A

ultramicrotome

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Before infiltration with such media, the fixed tissue must undergo dehydration by having its water extracted gradually by transfers through a series of increasing ethanol solutions, ending in

A

100% ethanol

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The ethanol is then replaced by an organic solvent miscible with both alcohol and the embedding medium, a step referred to as______ because infiltration with the reagents used here gives the tissue a translucent appearance.

A

clearing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The fully cleared tissue is then placed in_______ in an oven at______, which evaporates the clearing solvent and promotes infiltration of the tissue with paraffin

A

melted paraffin

52°-60°C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Embedding materials include paraffin, used routinely for_____

A

light microscopy

17
Q

plastic resins, are adapted for both
___\ and _____ microscopy

A

light and electron microscopy

18
Q

Embedding is allowing it to harden in a small container of paraffin at

A

room temperature

19
Q

Tissues to be embedded with plastic resin are also dehydrated in ethanol and then infiltrated with plastic solvents that harden when cross-linking_______ are added.

A

polymerizers

20
Q

avoids the higher temperatures needed with paraffin, which helps avoid tissue distortion.

A

Plastic embedding

21
Q

Paraffin sections are typically cut at_____ thickness for light microscopy

A

3-10 μm

22
Q

electron microscopy requires sections less than _____ thick.

A

1 μm

23
Q

The sections are placed on glass slides and stained for light microscopy or on metal grids for electron-microscopic staining and examination

A

Mounting