TB 162, Metrorail Construction Flashcards

1
Q

A 46 inch water supply systemprovides cooling for the tunnel boring machine and water for firefighting operations. The system is equipped with 2 1/2 inch outlets every?

A

200 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The greatest risk in tunnel construction is?

A

Compromised atmospheres

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The fire department will respond to ? Portal entrances, during construction of the MRCTC project.

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

A contractor maintains a hardwired mining phone system during totaling operations. It is equipped with the phone located at the following locations?

A

On the tunnel boring machine,
at the cross passages,
at the portals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If the atmosphere in the tunnel is compromised, entry is limited to?

A

US and R certified members wearing rebreather’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Cal\OSHA requires that telling contractors provide rescue team personnel that meet specific training requirements if more then ? workers will be operating in the tunnel or shaft. LAFD has agreed to be the rescue team as we meet the requirement of having a rescue team on the site within? Minutes.

A

10

30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

For an EMS incident that occurred below grade,? Are required.

A

Full PPE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

By law, to provide a means for escape for me has just non-breathable atmosphere, all personnel who enter a mining site must wear?

A

A one hour self rescue device

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The direct fire attack inside the tunnel should only be justified if?

A

There is a possibility to save a life

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Members entering a compromised atmosphere under the conditions listed with the 60 minute bottle for limited to ? minutes working time.

A

12 minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Engineers pumping into fire department connections during construction jump rope a maximum of?

A

150 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The first unit on scene assignments his\her company to?

A

Lobby\systems control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The second arriving company establishes?

A

Staging

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The agency in charge of an incident is?

A

The LAFD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The third company operates in the portal adjacent to the tunnel and is responsible for?

A

Technical support

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Fire protection systems found in the portals include all the following?

A

Fire detection devices,
extinguishing systems,
emergency lighting

17
Q

The tank in\tag out system used for identifying employees below grade is referred to as the brass board. The Brass board is located?

A

Adjacent to the entry portal

18
Q

Self rescue were respirators are maintained and stored at?

A

Each portal of entry

19
Q

The first alarm assignment is deployed to establish?

A

Base,
staging,
obtain initial observations

20
Q

The first arriving U.S. and R certified company establishes?

A

TUNNEL

division

21
Q

The responsibility for establishing rapid intervention is?

A

The back up entry team

22
Q

Which of the following methods of communication is not permitted in the tunnel?

A

Department issued cell phone

23
Q

Cal\OSHA has listed the metro regional connector transit Corredor project as potentially gassy due to the possibility of encountering methane gas. Hazard mitigation is been identified through?

A

Constant air monitoring,

use of ventilation system

24
Q

The third company of the first alarm assignment arriving at a tunnel construction incident establishes and is responsible for?

A

Technical support

25
Q

The first unit on scene gives a radio size up, assumes the initial responsibility of incident commander, and assigns his/her company to?

A

Lobby/systems control

26
Q

The second company of the first alarm assignment arriving Alta tunnel construction incident establishes?

A

Staging above round in proximity to the portal opening

27
Q

Lobby/systems control is normally located?

A

In the contractors trailer

28
Q

All of the following types of incidents within a non compromised atmosphere, members must wear an SCBA and a self rescue device ready for use?

A

EMS, injury, heart attack, electrocution
Physical extrication from equipment
Confined space rescue
Collapse or flooding with rescue

29
Q

An SCBA and a self rescue respirator is required for entry into a known compromised atmosphere, however personnel are limited to initial observation or atmospheric testing when which of the following conditions are met?

A

A two member team is in sight of the tunnel or shaft opening
A four member team, if they will be ou of sight of the tunnel or shaft opening
A back up team is standing by
Entry into a compromised atmosphere does not exceed a distance of 500 feet

30
Q

Radio communication in the tunnel with LAFD 800 MHz radios will be?

A

In the direct mode

31
Q

A contractor hardware communication system is installed within the tunnel provides a telephone headset designed to maintain communications within the tunnel and above grade located.

A

At each portal or station box
At each cross passage
Every 1000 feet within the tunnel

32
Q

All emergency operations will be discontinued and the tunnel evacuated should the tunnel atmosphere meet or exceed ? Lower explosive limit

A

20

33
Q

The officer from the first arriving US&R certified company establishes ? In the portal, adjacent t the tunnel while the remainder of the company ?

A

Tunnel division

Prepares for tunnel operations