BOOK 100 Hi rise IC Flashcards
primary responsibility of the initial fire attack team is to …
locate, identify the emergency and determine the scope
when an actual fire is located, the officer of the attack team is designated the ?
division supervisor
a hi rise fire attack team takes specific equipment with them on an investigation what are they?
scba
forcible entry tools
hose packs
TIC
what unit is responsible for transport of equipment via stairwell in a Hi rise?
Ground support
how many feet shall BASE be from the building and not in proximity of the CP?
200 feet
list command staff?
PIO, safety, liaison
once fire attack begins in a hi rise, two members enter and two members remain where?
outside the IDLH
elevators used in a hi rise incident, shall not go higher than ? reported floor/lowest alarm floor
2.2
staging will normally be?
two floor below fire
who monitors the built in fire control, comms and elevator systems?
systems control unit
where is an appropriate location for RIC for rapid deployment?
staging or floor below the fire
who provides medical aid and transportation for injured and ill personnel?
medical unit
normally how many companies should be kept in base for each company held in staging?
2:1
how far is a safe location for the occupants during a hi rise incident?
200 feet
the command staff support staff are called?
assistants
what information should be relayed when the fire attack team has located the emergency?
location, nature and extent of the problem
what is the responsiblity of the second arriving company responsible for in a hi rise incident?
controlling elevators and vertical access routes
what are the basic requirements of the ICS has been met with the establishment of ?
fire attack, lobby control, staging and base
medical group super would recieve orders from and report to?
Operations
the time to consider for early relief on an actual hi rise fire is?
10-15 minutes
who is responsible for verifying water supply into the standpipe system at a hi rise?
lobby control
if an additional water supply is needed via the stairwell, who is responsible for providing a supply line to the entrance of the stairwell?
Base
the individual in charge of staging in a high rise fire is known as?
area manager
protecting the fire pump room from flooding and power loss is the responsibility of?
ground support unit
the responsiblity of providing operators for elevator operations rest with?
lobby control
the systems control unit leader will be located in, or adjacent to?
the fire control room/area
high rise ; base may be established by?
available engineers from the first alarm assignment
the responsiblity for priority movement of personnel and equip. between base and staging lies with?
lobby control
a hi rise building is define as a building which is over?
75 feet, ground level access to floor level of highest floor
hi rise buildings are designed with how many hour fire resistance between floors and around vertical openings?
2 hours
the objective for fire suppression force in a hi rise is to ?
locate, confine and extinguish
upon arrival at a high rise fire an an evacuation is underway, attempt should be made to?
attempt to gain control of the evacuation
commercial hi rise buildings are characterized by?
center core construction
circuit corridors around the core
larger, more open spaces
which of the following poses the greatest danger to occupants during a high rise fire?
exposure to smoke and products of combustion
the most effective means of saving lives and facilitating rescue in a hi rise fire emerg. is?
aggressive attack on fire
wehn conducting a search during a hi rise fire, the company entering an entry door shall place a ?
single slash and company designation on the entry door to the right of the slash
hi rise occupancies designed for human occupancy are divided into what two types?
residential and commercial
when ascending via stairwells the fire attack officer should check floor status every?
4-5 floors
when an evacuation is underway prior to the fire dept. arrival, firefighters must make their way to each landing and attempt to control exiting occupants, beginning at ?
the second floor
preplanning hi rise fires, also involves?
working knowledge of the building
optimum physical conditioning
understanding hi rise ICS and company SOP
building occupants who call 911 to report being trapped within a hi rise building fire can be managed by ?
communication tech specialist; command post
as the fire attack officer, once you have identified the fire floor, before opening the stairwell door you shall?
check the floor above and report you findings to the IC
unless fire conditions dictate otherwise, the best place to connect toa building standpipe is?
fire floor
when a hi rise fire exist and the buildings exterior entrance is locked, the first priority is to?
gain effective access
a minimum number of personnel needed before an elevator is used to go aloft is?
5
no more than how many personnel, with required equip shall be permitted in any one elevator at a time during phase 2 opeations?
6
elevators installed after oct. 1985 must have a separate button for use by emergency personnel. what is that button named?
call cancel
a FD member shall be designated to control the car opeation. this operator reports to?
lobby control unit
what position, on the lobby emerg. service key switch is use to place the elevator in operation on a temporary basis when the entire building has been deemed safe for normal use?but there is residual smoke remaining to activate associated smoke detectors
bypass
the first fire suppression resource discovers that all elevators have been recalled to the lobby or designated level. proper procedures indicate?
the lobby emerg. service switch shall be activated
elevators to go aloft during a hi rise fire shall make precautionary stopes every ? these precautionary stops test and confirm that the elevator is operating properly in?
5 floors
phase 2 mode
using elevators for asscent should determine the location of stairwells in relationship to the elevator. when should this be accomplished?
first and subsequent precautionary stops
elevator ascent during investigations for fires shall only be used when the reported location is above what floor?
6
hi rise building greater thatn 150’ equipped with fire protection water system with a fire pump,fire dept. connections, a combination standpipe system with 1 1/2 “ outlets on the floors would be built between what dates?
1960-1974
the most important fire protection system provide to protect a hi rise and its occupants is?
water systems
what standpipe stystem is the total water supply delivered by FD apparatus through inlet connections?
class1
what system is required for a high rise building built from 1960-1974
class 3 combo system
diesel pumps are required to have a separate fuel supply and separate fuel supply tank for each engine. fuel supplies shall last a minimum of?
4 hours for existing hi rises and 8 hours for post 1974
what is installed to prevent the fire pump from continually starting and stopping?
jockey pump