SPRING 2019 WEEK 2 Flashcards
- Regarding the use of the Search Rope at fire operations, which point below is correct?
(TB Rope 6 — 6.3, 7.1, 7.2, 8.2)
A. Searches off the rope are not to be conducted unless approved by the Sector Chief or IC
B. Under most conditions, the number of members assigned to the Search Ropej should be
limited to four
C. A unit (other than 1
st alarm) ordered to search an area requiring the use of a Search Rope
should maintain unit integrity and perform this function with all members operating as the search
team on the search rope
D. If a company is ordered to relieve another unit at a forward point of the search, the
relieving company should enter the area to be searched with their right hand in contact with the
search rope (if possible)
D
- Regarding the inspection and usage of the PSS, it would be incorrect to state it?
(TB Rope4 — 2.1, 2.2, 5.1.1, .5.1.2, 5.4.1, 5.4.6)
A. Is a one-time use system; after use it is to be placed out of service
B. Is only to be used as a last resort
C. Should be inspected at the start of each tour. If any doubt exists about the serviceability of
any component of the PSS, it shall be placed out of service
D. Should be repacked and inspected quarterly as part of the quarterly Safety Equipment
Inspection
E. Should be inspected after concluding operations; members should inspect the outside of the
bag for any signs of exposure to heat, defects and / or contamination
D
- Ladder 44 returns from a 2
nd alarm fire in an H-type building where two members used
their PSS, which must both be placed out of service. Regarding the placing of the PSS out of
service, it would be incorrect to state? (TB Rope 4 — 6.9,6.15,6.16)
A. The Officer must complete an Out of Service Life Safety Equipment Report (SCF-2) and
forward it through the chain of command to the Chief of Safety
B. An investigation of the circumstances as stated in the (SCF-2) report is required by the
Battalion Chief on duty, and should be indicated in the Chiefs endorsement
C. If a firefighter is not equipped with a PSS and a response is received, the firefighter will
respond with their unit, and that member shall be counted towards that unit’s staffing, but shall
not enter or operate in an IDLH
D. When a Chief Officer or Company Officer is not equipped with a PSS, the unit they are
working in shall be placed out of service until a replacement PSS is obtained
C
First alarm units arrive at the scene of a reported odor of smoke in a 60-story High Rise
Office Building that was constructed in 2017. On arrival, the Fire Safety Director indicates
that an HVAC detector has activated on the 30th
floor. There are 3 elevator banks in the
building: the A Bank serves floors 1-20; the B Bank serves floors 20-40: the C Bank serves
floors 40-60.
- Regarding the engine operations at this fire, it would be correct to state that?
(FFP High-Rise - 9.3.IB, 9.4.1—B, E, F)
A. The first engine should remain at the Fire Sector post on the floor below the reported fire
floor, until the first ladder has verified the fire location.
B. The second engine should report to the vicinity of the standpipe outlet with a Post radio to
provide a communication link between the lobby and the fire area pending establishment of a
Fire Sector / Branch
C. The second engine officer should remain at the standpipe outlet to provide HT
communications between the standpipe outlet and the nozzle until the first hose line has been
supplied with water
D. The second engine should not enter the fire area at all, so as not to deplete their air supply
B
First alarm units arrive at the scene of a reported odor of smoke in a 60-story High Rise
Office Building that was constructed in 2017. On arrival, the Fire Safety Director indicates
that an HVAC detector has activated on the 30th
floor. There are 3 elevator banks in the
building: the A Bank serves floors 1-20; the B Bank serves floors 20-40: the C Bank serves
floors 40-60.
- The 4th
arriving ladder would be correct to think that they should? (FFP High-Rise—
8.6.1A-2, B-3, C, E, G, H, I)
A. Take the high-rise bank to gain access to the roof
B. Advise the SAE Group Supervisor of all means available for roof ventilation. Roof
ventilation shall not be initiated unless ordered by the SAE Group Supervisor
C. Conduct a primary search of floors 55-60
D. Drop down to the upper floors of the B Bank when initial operations are completed on the
upper floors of the building, unless otherwise ordered by the Incident Commander
E. Operate under control of the Fire Sector Supervisor until the SAE Group is established
A
- BC Question - Regarding the use and operations of the Decon Shower Apparatus (DS A), it
would be incorrect to state that? (HM 15 — 1.1, 1.2, 1.4, 4.3, 4.4)
A. DSA can be used to address nuisance contamination, contaminants not immediately life�threatening or residual contamination after emergency gross decon
B. A Haz-Mat Technician Unit must be present to ensure proper precautions are taken
C. The IC will give a location where the Decon Shower Apparatus should be positioned
D. The DSA should be positioned at the end of the contamination reduction corridor
E. Proper positioning of the DSA is indicated when the rear half of the apparatus is in the hot
zone behind the hotline
E
- Ladder 157 returns from a fire where inside team members were exposed to high heat
conditions. All members then inspect their PSS equipment, and they note the following:
• The Officer’s PSS bag and harness are melted from heat exposure
• The Can FF’s PSS bag shows discoloration from heat exposure
• The Irons FF’s PSS bag shows charring from heat exposure
• The OV FF’s rope is discolored in spots indicated by dark shading to the rope
In this situation, the Officer would be correct to place the entire PSS System out of service for
which members? (TB Rope 4 — 5.3.3, 5.4.3)
A. Officer only
B. Officer and Irons
C. Officer, Can, and Irons
D. Officer, Can, Irons, and OV
C
- A ladder company officer is deploying a Search Rope at a 10-75 for a fire in a large area
commercial occupancy. After securing the end of the Search Rope to a substantial, non-movable
object outside, he was incorrect in which action? (TB Rope 6 — 5.4, 5.5, 5.6, 5.9)
A. He wore the bag over his shoulder, then payed out the rope keeping it taut, and maintaining
a handhold on it at all times
B. He tied the rope off at intervals to keep it taut, and also tied the rope off when he changed
direction or grade
C. He maintained the rope 6-12 inches above the ground to keep it out of water
D. When he became low on air and requested relief, there was nothing to tie off to, so he took
a few wraps around the bag with the rope
C
- Local law 26 of 2004 was promulgated to address non-fire emergencies in Class E and
Class B Office buildings and mandates an Emergency Action Plan for these occupancies.
Regarding this local law, which point is incorrect regarding significant emergencies in these
buildings? (FFP High-Rise—3.1,4.2, 4.3 Note)
A. A Building Information Card (BIC) must be maintained at the Fire Command Station. This
BIC can be used by the FDNY IC at fires or emergencies to develop strategies or make tactical
decisions
B. A list of special needs occupants and their location in the building—who have requested
assistance if the EAP is implemented—must be maintained at the Fire Command Station
C. The IC can direct the EAP Director to make announcements to occupants as necessary
D. The use of elevators by building personnel to move occupants is not permissible if the EAP
has been implemented.
D
- BC Question - A Battalion Chief has just operated at a 10-77 / 2
nd alarm where the Fire
Window Blanket from Ladder 134 was deployed by Engine 268. After the fire is placed under
control, the BC must perform the follow-up procedures as the Deputy Chief has another fire to
respond to. In this situation, it would be incorrect for the BC to? (TB Tools 3 — 4.1,4.2, 4.3)
A. Secure the Blanket until the arrival of the Safety Battalion or their designee
B. If the Safety Battalion is not available, secure the Blanket and notify R & D
C. Have the Officer of Engine 268 prepare a brief letterhead report to the Chief of Operations
via the chain of command with a copy to the Chief of the Fire Academy
D. Have Ladder 134 request a replacement Blanket from R and D if it is during normal
business hours, or contact SOC at Roosevelt Island after business hours
C
Use the following scenario to answer questions 13 - 14:
Members are operating at a 10-75 when after the fire is controlled, they determine they
have been exposed to synthetic opioids during the firefighting operations.
13. Regarding the decontamination of the members PPE, they should? (HM 18 — 5.2)
A. Spray the bunker gear with copious amounts of water, so it will excessively drip off
B. Spray the bunker gear with just enough water to lightly wet it, so it will not excessively
drip off
C. Spray the bunker gear with a medium amount of water, so it will significantly drip off
D. Not wet the bunker gear at all. Instead, leave it dry, and have the gear removed using
techniques to prevent aerosolizing powdered contaminants
B
First alarm units arrive at the scene of a reported odor of smoke in a 60-story High Rise
Office Building that was constructed in 2017. On arrival, the Fire Safety Director indicates
that an HVAC detector has activated on the 30th
floor. There are 3 elevator banks in the
building: the A Bank serves floors 1-20; the B Bank serves floors 20-40: the C Bank serves
floors 40-60.
- The Officer of the 3
rd
to arrive Ladder Company would be correct to think that his unit
should? (FFP High Rise—8.5.IB—2, 3, 4, 5, 6)
A. Take the attack stair to the floor above, the 31st
floor, and conduct a primary search on that
floor
B. Determine which stair is the best stairway to be used for evacuating occupants and advise
the Fire Sector Supervisor of this fact
C. Check the floor above for heat, smoke, evacuation, and fire extension. Also check to
determine if there are access stairs down to the 30th
floor, or up to the 32nd floor
D. Examine all stairways for occupants and smoke condition. If difficulty is encountered
clearing the attack stair of occupants, advise the first arriving engine officer or the Fire Sector
Supervisor to withhold the attack until occupants have been safely removed
C
- The Postal Service has Bio-Detection Systems (BDS) in various mail handling facilities
throughout NYC that will detect anthrax which has been placed in the mail. When a BDS alarm
alerts, it will be treated as a presumptive positive for anthrax. Regarding the FDNY response to
these facilities, it would be incorrect to state that? (HM 14 — 3.1, 4, 5, 6.1)
A. The FDNY mission at BDS operations is to triage, treat and decontaminate anyone that
may have been exposed to anthrax.
B. If a BDS alarm is activated, the dispatcher will alert units that they are responding to a
BDS alarm. However, units shall always verify the type of incident whenever they respond to a
USPS bulk facility in case the alarm is received from a source other than the BDS alarm
C. FDNY members in proper PPE will conduct primary and secondary searches of the facility.
D. The USPS facility will be treated as a crime scene and the FBI will take over as lead
investigators. FDNY units shall conduct operations as per AUC 317—crime scenes.
C
Answer questions 1-7 based on the following scenario:
First alarm units respond to a 10-76 for fire on the 22nd
floor of a 56-story High Rise Office
building in January on a cold winter night. There are 3 elevator banks in the building: the
A Bank serves floors 1-19; the B Bank serves floors 19-38: the C Bank serves floors 38-56.
There are access stairs from floors 25-27. There is a positive stack effect in this building, so
there is no smoke condition on the floors below, allowing the Fire Sector and Forward
Staging Areas to be set up at their preferred locations.
- At this fire, members should expect that the Forward Staging Area would be established on
thefloor. (FFP High Rise - 6.6.2—A)
A. 21st B. 20th C. 19th D. 18th
B
- BC Question - Regarding the need to decontaminate patients or FDNY personnel, this
decision will be made by the FDNY IC in consult with the? (HM 16 — 2.1.4)
A. NYPD IC
B. Haz Mat Battalion and EMS Haz-Tac Officer
C. City Wide Tour Commander
D. Haz-Mat Battalion
B
- If the address of a fire or emergency is not a CIDS building, but is on the same side of the
street and is within? (Comm 4 — Page 4-2)
A. Two house numbers of a CIDS building, the dispatcher will always notify the IC of this
fact via radio
B. Three house numbers of a CIDS building, the dispatcher will always notify the IC of this
fact via radio
C. Two house numbers of a CIDS building, the dispatcher will notify the IC of this fact via
radio if preliminary or progress reports indicate exposures are a consideration
D. Three house numbers of a CIDS building, the dispatcher will notify the IC of this fact via
radio if preliminary or progress reports indicate exposures are a consideration
D
First alarm units arrive at the scene of a reported odor of smoke in a 60-story High Rise
Office Building that was constructed in 2017. On arrival, the Fire Safety Director indicates
that an HVAC detector has activated on the 30th
floor. There are 3 elevator banks in the
building: the A Bank serves floors 1-20; the B Bank serves floors 20-40: the C Bank serves
floors 40-60.
- Units should expect which of the following to occur at this alarm? (7.2.5 A-l, 2,
5, 6, 7, B)
A. Elevators will be automatically recalled
B. Fire alarm signals will be sounded on only the 30th
and 31st
floor
C. Air supply into and return air from — will be stopped on only the 30th
and 31st
floors
D. Air exhaust fans and dampers in the smoke shaft will be activated or pressurizing fans in
stair enclosures will be activated
E. Doors on the locked fail-safe system will unlock
D,E
Answer questions 4-6 based on this scenario:
You are the officer of a ladder company that arrives first at the scene at a USPS Bulk Mail
Facility BDS alarm activation with an engine company. You meet with a USPS liaison and
determine there is a confirmed BDS activation.
- Regarding entry into the facility for “Immediate Life Safety” issues, the ladder officer
would be correct to think that at a confirmed BDS alarm? (HM 14 — 8.1)
A. Bunker Gear and SCBA are not satisfactory under any circumstances
B. Bunker Gear and SCBA may be used if a higher level of PPE is not available, provided that
as soon as possible, an Emergency Decon Area is established and a Backup team designated
C. Bunker Gear and SCBA may be used if a higher level of PPE is not available, provided that
prior to entry, an Emergency Decon Area is established and a Backup team designated
D. Only Haz-Mat Technicians in proper PPE may enter for Immediate Life Safety issues.
C
First alarm units arrive at the scene of a reported odor of smoke in a 60-story High Rise
Office Building that was constructed in 2017. On arrival, the Fire Safety Director indicates
that an HVAC detector has activated on the 30th
floor. There are 3 elevator banks in the
building: the A Bank serves floors 1-20; the B Bank serves floors 20-40: the C Bank serves
floors 40-60.
- The first and second ladder company should both work together to provide a coordinated
primary search of the fire floor and evacuate the fire floor as necessary. If possible, they should
both attempt to use the same elevator car, staffed by a member of the first ladder company to
provide safe access to the fire area. (FFP High-Rise—8.4.2 A-l, 2, 4)
A. Agree or D. Disagree?
A
First alarm units respond to a 10-76 for fire on the 22nd
floor of a 56-story High Rise Office
building in January on a cold winter night. There are 3 elevator banks in the building: the
A Bank serves floors 1-19; the B Bank serves floors 19-38: the C Bank serves floors 38-56.
There are access stairs from floors 25-27. There is a positive stack effect in this building, so
there is no smoke condition on the floors below, allowing the Fire Sector and Forward
Staging Areas to be set up at their preferred locations.
- Units directed to report to the SAE Group Supervisor at this fire should know that he will
be located on at least theor higher?
A. 27lh
floor B. 28th
floor C. 38th
floor D. 39lh
floor
D
Answer questions 8-9 based on this scenario:
First alarm units arrive on scene of a suspicious package where there a suspected powder I
anthrax incident and NYPD is not on scene.
8. In this situation, they would be incorrect to think that? (HM 16 — 2.1.2, 2.2.2)
A. A 10-80 should be transmitted specifying suspected anthrax and an immediate request
made for the response of NYPD
B. Ambulatory patients may be isolated by having them walk away from the area of exposure
C. Patients reporting that they were contaminated who have visible powder on their skin or
clothing should be asked to remove their outer clothing and provided with a disposable garment
or sheet. This clothing should be bagged in a clear plastic bag.
D. Emergency Decontamination should not be utilized in these situations regardless of the
patient’s medical assessment
D
PART II - TRAINING BULLETINS - TOOLS #2 & 3
1. An officer drilling on the KO Curtain was correct to state that? (TB Tools 2 —
1,3.1, 6.3)
A. Its dimensions are 10’ x 12’ and it weighs 40 pounds
B. It has four—10 foot long fire-proof ropes, one at each end of the curtain.
C. It should be inspected daily and after each use
D. If there is any doubt as to the serviceability of the KO Curtain, it should be placed out of
service
D
Answer questions 4-6 based on this scenario:
You are the officer of a ladder company that arrives first at the scene at a USPS Bulk Mail
Facility BDS alarm activation with an engine company. You meet with a USPS liaison and
determine there is a confirmed BDS activation.
- BC QUESTION - As the first arriving BC, you would be correct to consider which point?
(HM 14 — 7.1,9.1)
A. You should report to the Incident Command Post
B. The TAC-U Channel should be established
C. FDNY units will be responsible for decontamination of Postal Groups 1, 2, and 3
D. Haz-Mat Technicians wearing appropriate PPE will enter the Safe Refuge Area to monitor
the environment and set up and assist with the decontamination process
D
Answer questions 4-6 based on this scenario:
You are the officer of a ladder company that arrives first at the scene at a USPS Bulk Mail
Facility BDS alarm activation with an engine company. You meet with a USPS liaison and
determine there is a confirmed BDS activation.
4. In this situation, you would be correct to think that during the initial stages of the operation
you should? (HM 14 — 6.1,8.1)
A. Not enter the facility under any circumstances
B. Enter the facility only to perform a size-up and a primary search
C. Enter the facility only if there is an immediate life hazard that needs to be addressed
D. Enter the facility only if directed to do so by senior Postal Officials
at the ICP
C
- An additional ladder company (above the FAST Truck) shall be assigned by the dispatcher
when the first two ladder companies are responding with 4 firefighters to any? (Comm 6
— 6.9.1)
A. Reported structural fire
B. Reported fire or emergency
C. Incident—only if a 10-75 is transmitted
D. Incident—only if a 7-5 signal is transmitted
C
Members are operating at a 10-75 when after the fire is controlled, they determine they
have been exposed to synthetic opioids during the firefighting operations.
- BC Question - After the Bunker Gear is removed from members, the IC should know that
thewill determine the decontamination method for the PPE? (HM 18 — 5.2)
A. Haz-Mat 1
B. Safety Battalion
C. Decon Support Unit in consult with the Haz-Mat Battalion
D. Safety Battalion in consult with the Haz-Mat Battalion
C