Spray Ponds Flashcards

1
Q

The design basis for the Ultimate Heat Sink requires sufficient cooling for a period of ______ without water makeup to cool down the unit and maintain it in a safe condition under the most adverse historical meteorological conditions.

A

26 days

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

One of the design bases of the Spray Pond (Ultimate Heat Sink)is to provide sufficient cooling for a period of ____ days without _________ to cool down the unit and maintain it in a safe condition under the most adverse historical meteorological conditions.

A

26, water makeup

12’ is the water volume that would be depleted over 26 days following a design basis LOCA if no makeup were available.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What components does the Spray Pond system cool?

A
  1. EW heat exchangers
  2. DG heat exchangers:
    • lube oil cooler
    • fuel oil cooler
    • turbocharger
    • discharge air intercoolers
    • jacket water cooler.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The minimum spray pond level for spray pond pump operation (NPSH) is _____ and the Tech Spec levels are _____for the control room indication and _____ locally

A

1’ 6”
14’0”
13’6” (12’ plus 1’6” for NPSH)

The 12’ is the water volume that would be depleted over 26 days following a design basis LOCA if no makeup were available.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Each spray pond has ______ spray headers with ______risers. Each riser has _____ nozzles for a total of _____ nozzles per pond.

A

4, 20, 4, 320

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

State the conditions that will auto start the spray pond pumps.

A
  1. Diesel Generator running
  2. SIAS or CSAS
  3. CREFAS
  4. CRVIAS
  5. AFAS
  6. LOP
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The spray pond pump house exhaust fan starts when when the pump is started and it turns off ___ minutes after the pump is stopped.

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When securing a spray pond filter pump, what must be done prior to stopping the pump and why?

A

You must close the pump discharge valve prior to securing the pump to ensure that the pump casing does not drain back to the pond and necessitate extensive priming of the pump when a start is desired.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

An area operator is performing a spray pond filter backwash and gets distracted and leaves without securing the backwash. What will happen to spray pond level with no further action?

a. The level will stop lowering at 13’11” when the backwash valves will auto close on a low spray pond level signal
b. The level will lower until the the filter pump trips at a spray pond level of 13’7.5”
c. The level will lower continuously unless action is taken
d. The level will initially decrease until automatic DS makeup actuates at 13’11”

A

b

The filter pump will automatically restart when the low level signal clears.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which one of the following is NOT an analysis performed by chemistry on the spray ponds?

a. Zinc
b. Phosphates
c. Chlorine
d. Silica

A

b

The analyses performed are :
Chlorine
Silica
Zinc
MBA - microbiological activity
Conductivity
Radioactivity
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The chemicals added to the spray ponds to kill bacteria and reduce bacteria related corrosion are ______ and _______.

A

sodium hypochlorite (chlorine) and biocide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

______ acid is added to the spray ponds to lower pH as needed:

a. Sulfuric
b. Muriatic
c. Hypochloric
d. Boric

A

a

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Regarding the two make sources to the Spray Pond System, _____ makeup has more calcium, but less biological activity.
A) TB, Cooling Tower Makeup and Blowdown System
B) DS, Domestic Water System
C) DW, Demineralized Water System
D) PW, Plant Cooling Water System

A

B) DS, Domestic Water System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Isolating which of the following Spray Pond System ‘A’ components will result in Spray Pond Inoperability per Tech. Spec. 3.7.8?
A) ‘A’ DG Jacket Water Cooler
B) Spray Pond Backwash Filters
C) All Diesel Generator Coolers on ‘A’ Train
D) ‘A’ Essential Cooling Water Heat Exchanger (Spray Pond side ONLY)

A

D) ‘A’ EW Heat exchanger

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
According to the bases for LCO 3.7.9, the Ultimate Heat Sink temperature should no exceed \_\_\_\_ degrees F and the level of each Essential Spray Pond should not fall below \_\_\_\_\_ feet usable water depth during normal operation. 
A) 98, 12.0
B) 89, 12.0
C) 89, 13.5
D) 98, 13.5
A

B) 89F, 12.0 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Normal power supply for the spray pond acid, specialty chemical pumps and recirculation pumps is _________, which is located _______.

A

NHN-M30, In the yard just plant west of the chemical addition pump house.

17
Q

With regards to spray pond makeup water, DS has more _______ and TB has more________.

a. Calcium, Biological activity
b. Phosphates, Calcium
c. Biological activity, Calcium
d. Biological activity, Chlorides

A

a

18
Q

What spray pond indications are available on multipoint recorder 1JRMNTJR1 on B07?

A

Spray Pond pump motor temperature (Upper and Lower Bearings) are displayed on multipoint recorder 1JRMNTJR1 on B07.

PT 01 SPA-P01 MOT UP BRG SPNTE181
PT 02 SPA-P01 MOT LOW BRG SPNTE183
PT 03 SPB-P01 MOT UP BRG SPNTE180
PT 04 SPB-P01 MOT LOW BRG SPNTE182

19
Q

MSCI, CCI, biocide and dispersant are pumped into the spray pond by the individual ______ pumps via ______ valves into the recirculation headers. The discharge of the _______ pumps supplies the recirculation pumps. PS…this is a useless question.

A

chemical metering, quill, spray pond filter

20
Q

Bypass Operation during Modes 1-4…

A

…will place the Spray Pond system outside it’s design bases.

21
Q

Essential Spray Pond Pumps (designated SPA-P01 and SPB-P01) are powered from

A

SPA-P01 from PBA-S03

SPB-P01 from PBB-S04