Natural gas is lighter than air, what will it do in an outside environment?

A

Dissipate rapidly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does natural gas do in buildings?

A

Pockets in attics and dead spaces

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the flammable limits of natural gas?

A

4-15% in air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Natural gas is non-toxic, but how does it pose a health hazard?

A

Displaces oxygen, causing asphyxiation if in a confined space

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How can flammable gas ranges of natural gas be determined?

A

Combustible gas indicator CGI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Why should burning natural gas be allowed to burn?

A

Because it keeps it visible. If it is not visible, is also has an explosive potential because its not being burned

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How should natural gas fires be controlled?

A

By stopping the flow of natural gas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Where should apparatus be parked at natural gas incidents?

A

Uphill and upwind to avoid becoming an ignition source for the gas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which company needs to be dispatched to natural gas emergencies?

A

SCG…verify their response with NHFD dispatch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What must be a consideration at building explosions which do not have natural gas in them?

A

Natural gas as the cause due to underground leaks in pipes or cracks in ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which units/resources are equipped with CGI?

A

Both squad companies and gas company

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Who must be notified to verify structural stability of buildings involved in an explosion or gas incident?

A

Building department

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Hand Lines and large caliber hose lines may be used for what?

A

Dissipation of vapor accumulation or fire protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What are the gas companies responsible for?

A

Locating and eliminating gas leak sources

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What PPE shall personnel wear when working in the vicinity of a known or suspected gas leak

A

Full PPE with SCBA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What shall members operating in a suspected ignitable atmosphere do when attempting to shut off a gas line?

A

Breathing air from SCBA and be covered by a manned protective hoseline

17
Q

What type of zone shall be established and maintained around any suspected gas leak?

A

An exclusionary zone

18
Q

What type of tape shall be used to identify the exclusionary zone during a gas leak?

A

Fire line tape