S/G Tube Leak AOP Flashcards

1
Q

What radiation monitors might alarm during a S/G Tube Leak?

A
  • SRA-1900/2900 (SJAE)
  • SRA-1800/2800 (GSLO)
  • DRA-300 (S/G Blowdown Sampling)
  • DRA-353 (S/G Blowdown Treatment)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What conditions during a S/G Tube Leak would require a Rx Trip? (Only a trip)

A
  • VCT level cannot be maintained.
  • > 50 gpm leakrate
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What conditions during a S/G Tube Leak would require a Rx Trip AND SI?

A
  • PZR level cannot be maintained with one charging pump and letdown is isolated.
  • > 100 gpm leakrate
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What conditions during a S/G Tube Rupture would require a shutdown and with what time requirements?

A
  • ≥ 75 gpd leakrate: Be in MODE 3 within 24 hours.
  • ≥ 150 gpd leakrate: Be in MODE 3 within 6 hours.
  • ≥ 75 gpd, but < 150 gpd and leakrate rate of change exceeds 30 gpd/hr: Reduce power to <50% in 1 hour and MODE 3 within next 2 hours.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the FOP criteria for S/G Tube Leak? (4022-002-021)

A

S/G Tube Leakage Criteria: If leakage is equal to or > 100gpm then:
- Trip Rx
- Go to E-0 step 1
- Initiate SI after verification of Rx trip.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

While isolating steam flow from a S/G with a Tube Leak, what setpoint is the leaking S/G PORV set to and why?

A
  • 1040#
  • Minimizes the spread of contamination.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

While performing S/G Tube Leak (4022-002-021) after the Rx has been shutdown, what criteria will require the operator to initiate SI?

A
  • PZR level cannot be maintained > 7%
    -OR-
  • Subcooling < 40F
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

While performing S/G Tube Leak (4022-002-021) after the Rx has been shutdown, what is the cooldown rate limit?

A

Equal to or < 100F in any one hour period.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the Tech Spec Limit for S/G Tube Leakage?

A

Limited to 150 gallons per day through any ONE S/G.