Permissives Flashcards
P-4 Conditions and Functions with Status Light ON
Conditions:
- Both RX Trip Breaker A (B) and Bypass Breaker A (B) Open
Functions:
- Low Tave for FWI
- Seals in FWI from SI or Hi-Hi SGWL
- Permits manual block of auto SI signals
P-4 Conditions and Functions with Status Light OFF
Conditions:
- Either RX Trip or Bypass Breaker racked in and closed
Functions:
- Prevents or defeats manual block of SI
P-6 Conditions and Functions with Status Light ON
Conditions:
- Any IR NI ≥ 10^-10 amps
Functions:
Permits manual block of SR High Flux Trip
P-6 Conditions and Functions with Status Light OFF
Conditions:
- Both IR NI < 6 x 10^-11 amps
Functions:
- Prevents/Defeats manual block of SR High Flux Trip
P-7 Conditions and Functions with Status Light ON
Conditions:
- 3/4 PR NI < 10% AND 2/2 Turbine Impulse # <10%
Functions:
- Permits auto block of “At Power” Trips
P-7 Conditions and Functions with Status Light OFF
Conditions:
- 2/4 PR NI > 10% OR 1/2 Turbine Impulse # > 10%
Functions:
- Prevents/Defeats auto block of “At Power” Trips with the exception of Turbine Trip
P-8 Conditions and Functions with Status Light ON
Conditions:
- 3/4 PR NI ≤ 29%
Functions:
- Permits auto block of Rx Trips due to single loop low flow trips AND Turbine Trip
P-8 Conditions and Functions with Status Light OFF
Conditions:
- 2/4 PR NI > 29%
Functions:
- Prevents/Defeats manual block of Rx Trip due to single loop low flow trip AND Turbine Trip
P-10 Conditions and Functions with Status Light ON
Conditions:
- 2/4 PR NI ≥ 10%
Functions:
- Permits manual block of:
1) PR High Flux Trip, Low Setpoint
2) IR Trip
3) IR Rod Stop
- Also:
1) Resets P-7
2) Backup De-energization of SR
P-10 Conditions and Functions with Status Light OFF
Conditions:
- 3/4 PR NI < 10%
Functions:
- Prevents/Defeats manual block of:
1) PR High Flux Trip, Low Setpoint
2) IR Trip
3) IR Rod Stop
- Also:
1) Inputs to P-7
P-11 Conditions and Functions with Status Light ON
Conditions:
- 2/3 PZR # < 1910#
Functions:
- Permits manual block of SI on low PZR #
P-11 Conditions and Functions with Status Light OFF
Conditions:
- 2/3 PZR # ≥ 1910#
Functions:
- Prevents/Defeats manual block of SI on low PZR #
P-12 Conditions and Functions with Status Light ON
Conditions:
- 2/4 Loop Tave ≤ 541 F
Functions:
- Allows manual block of SI due to low steam line pressure
- High Steam Flow = MSI
- Blocks all steam dumps
P-12 Conditions and Functions with Status Light OFF
Conditions:
- 3/4 Loop Tave > 541 F
Functions:
- Prevents/defeats manual block of SI due to low steam line pressure
P-13 Conditions and Functions with Status Light ON
Conditions:
- 2/2 Turbine Impulse # < 10%
Functions:
- Input to P-7