What should you do before starting the recovery process?
Empty the oil drain or make note of current level.
Robin Air CoolTech Instructions
What should you do after connecting the high and low side hoses?
Open the coupler valves on the hose ends.
Robin Air CoolTech Instructions
What button should you press to start the recovery process?
Press the RECOVER button.
Robin Air CoolTech Instructions
What happens when the system has recovered to 0 psi?
The vacuum pump will start and run until recovery is complete.
Robin Air CoolTech Instructions
What does the unit do after recovery is complete?
The unit goes into an automatic oil drain for up to 90 seconds.
Robin Air CoolTech Instructions
What will the display show after recovery is complete?
The display will show RECOVER COMPLETE RECOVERED XX.XX LBS. (X.XX KG) CHECK OIL BOTTLE.
Robin Air CoolTech Instructions
What must be injected back into the system during the Charging process?
The quantity of oil drained.