Refueling Flashcards
Given the following plant conditions: Mode 6. Refueling operations in progress. The refueling machine is moving to retrieve an irradiated fuel assembly in the upender. The CRS notifies the LSRO that there is a rapidly lowering fuel pool level and has implemented the LMEOP. The CRS directs the LSRO to place the fuel in a safe condition, and close PCN-V118 Fuel Transfer Tube Isolation Valve. Which of the following describes the required actions for the proper safe location of the fuel and location of the upender/carriage? The LSRO takes action to place the:
A. Fuel in the reactor vessel and retain the fuel carriage in containment.
B. Fuel in the upender and retain the upender vertical. Fuel Carriage either on the Fuel poolside or Containment.
C. Fuel in the intermediate storage rack and send the fuel carriage to the Fuel Building.
D. Fuel grappled at the uplimit on the RFM and lower the upender horizontal.
A. Fuel in the reactor vessel and retain the fuel carriage in containment.
The Unit is in Mode 6 with core off-load is in progress. Chemistry calls and reports that the Boron concentration is 2290 ppm in the RCS and 3010 in the refueling canal. The COLR limit is specified as 3000 ppm. What are all the action(s) if any that should be taken?
A. Suspend positive reactivity additions as soon as possible.
B. Initiate action to restore Boron concentration to within limits, suspend positive reactivity additions and core alternations immediately.
C. No action is required, refueling boron concentration is in specification.
D. Initiate action to restore Boron concentration to within limits, suspend core alternations within one hour.
B. Initiate action to restore Boron concentration to within limits, suspend positive reactivity additions and core alternations immediately.
The Concrete Cask heat removal system is OPERABLE if the:
A. difference between the average CONCRETE CASK air outlet temperature and ISFSI ambient temperature is greater than or equal to 102°F.
B. highest ISFSI outlet temperature is less than 102°F.
C. difference between the average CONCRETE CASK air outlet temperature and ISFSI ambient temperature is less than or equal to 92°F.
D. difference between the average CONCRETE CASK air outlet temperature and ISFSI ambient temperature is less than or equal to 102°F.
D. difference between the average CONCRETE CASK air outlet temperature and ISFSI ambient temperature is less than or equal to 102°F.
Which one of the following Radiation Monitors becoming inoperable would require suspension of core alterations during core offload? ASSUME all other conditions are acceptable/normal for the evolution.
A. RU 37, Power Access Purge Area Monitor
B. RU 33, Refueling Machine Area
C. RU 29, Control Room Ventilation Intake Monitor
D. RU 143, Plant Ventilation Low Range Monitor
B. RU 33, Refueling Machine Area
The unit is in Mode 6.
The core is being off-loaded to the Spent Fuel Pool.
I&C informs you that both Startup channels are incorrectly calibrated.
The following action(s) should be taken:
A. Suspend Core alterations and positive reactivity additions within 1 hour.
B. Determine the RCS boron concentrations by redundant methods immediately and every 12 hours thereafter.
C. Suspend Core alterations, suspend positive reactivity additions immediately and initiate action to restore one SRM to operable status immediately.
D. Initiate actions to restore one SRM to operable status within 4 hours and perform SR 3.9.1.1 (Verify boron concentration within limits of COLR) within 4 hours.
C. Suspend Core alterations, suspend positive reactivity additions immediately and initiate action to restore one SRM to operable status immediately.
Unit 1 is in Mode 6. Refueling is in progress.
The containment hatch is closed.
Refueling purge is in service.
If a Refueling Purge Exhaust Fan were to trip…
A. Spent Fuel Pool and Refuel Pool level will go down.
B. Spent Fuel Pool and Refuel Pool level will go up.
C. Spent Fuel Pool Level will rise, and Refuel Pool level will go down.
D. Spent Fuel Pool Level will lower, and Refuel Pool level will go up.
C. Spent Fuel Pool Level will rise, and Refuel Pool level will go down.
Design features prevent Spent Fuel Pool Level from inadvertently draining down to less than:
A. 130 ft 2 in
B. 130 ft 6 in
C. 131 ft 2 in
D. 131 ft 10 in
A. 130 ft 2 in
Mode 6.
Refueling operations in progress.
The refueling machine is moving to retrieve an irradiated fuel assembly in the upended.
The CRS notifies the LSRO that there is a rapidly lowering fuel pool level and has implemented the LMEOP.
The CRS directs the LSRO to place the fuel in a safe condition, and close PCN-V118 Fuel Transfer Tube Isolation Valve.
Which of the following describes the required actions for the proposer safe location of the fuel and location of the upender/carriage?
The LSRO takes action to place the:
A. Fuel in the upender and retain the upender vertical. Fuel Carriage either on the Fuel poolside or Containment.
B. Fuel in the reactor vessel and retain the fuel carriage in containment.
C. Fuel in the intermediate storage rack and send the fuel carriage to the Fuel Building.
D. Fuel grappled at the uplimit on the RFM and lower the upender horizontal.
B. Fuel in the reactor vessel and retain the fuel carriage in containment.
Given that Unit 1 is refueling with containment closed and fuel transfer canal in use, which of the following could cause Refueling Pool level to lower?
A. A Fuel Building supply fan trips.
B. Spent fuel temperature is raised.
C. A refueling purge supply fan trips.
D. Containment air temperature is lowered.
A. A Fuel Building supply fan trips.
Core re-load in progress.
Refueling Water Tank level is 14%.
Chemistry reports that the Refueling Pool boron concentration is not within limits.
Which one of the following actions is both available and procedurally directed as a makeup path that can be used to restore the refueling pool boron concentration?
A. Implement 40AO-9ZZ01, Emergency Boration, align HPSI pumps.
B. Implement 40AO-9ZZ01, Emergency Boration, align charging pump suction through CHN-UV-514 with BAMP pumps not available.
C. Implement 40EP-9EO11, Lower Mode Functional Recovery procedure, align charging pump suction to the alternate suction per SA-10, Charging Pump Alternate Suction to the RWT.
D. Implement 40EP-9EO11, Lower Mode Functional Recovery procedure, align charging pump suction to the Spent Fuel Pool per SA-11, Charging Pump Alternate Suction to the SFP.
A. Implement 40AO-9ZZ01, Emergency Boration, align HPSI pumps.
Unit 1 is in Mode 5 during a refueling outage.
‘A’ Train shutdown cooling is in service.
Spent Fuel Pool Level Hi or Lo is in alarm.
Spent Fuel Pool Level Lo-Lo is in alarm.
An Auxiliary Operator confirms Spent Fuel Pool level is 136 ft 6 inches and slowly lowering.
What is the current status of (a) LCO 3.7.14, Fuel Storage Pool Water Level (b) Spent Fuel Pool Cooling (c) and which procedure should be implemented to correct this condition?
A. (A) Entry in to LCO 3.7.14 is not required (B) SFP cooling must be secured at this level (C) 40AO-9ZZ23, Loss of SFP Level or Cooling.
B. (A) Entry in LCO 3.7.14 is required (B) SFP cooling can remain in operation at this level (C) 40AO-9ZZ23, Loss of SFP Level or Cooling.
C. (A) Entry in to LCO 3.7.14 is required (B) SFP cooling must be secured at this level (C) 40EP-9EO11, Lower Mode Functional Recovery Procedure.
D. (A) Entry in to LCO 3.7.14 is not required (B) SFP cooling can remain in operation at this level (C) 40EP-9EO11, Lower Mode Functional Recover Procedure.
B. (A) Entry to LCO 3.7.14 is required (B) SFP cooling can remain in operation at this level (C) 40AO-9ZZ23, Loss of SFP Level or Cooling.
Refueling pool level is 137’ 6” (>23 ft above the vessel flange).
Core RE-LOAD is in progress.
An irradiated fuel assembly is grappled and in the hoist box.
Train ‘B’ is under clearance for maintenance.
Train ‘A’ LPSI pump is gas bound.
Which ONE of the following complies with Technical Specifications 3.9.4 (Shutdown Cooling (SDC) and Coolant Circulation - High Water Level) required actions?
A. Core re-load may continue
B. Immediately stop core re-load, leave the fuel assembly in the hoist box.
C. Complete placing the fuel assembly in its designated core location, then suspend core re-load.
D. Immediately stop core re-load until you have verification that all activities that could result in boron dilution have been suspended.
B. Immediately stop core re-load, leave the fuel assembly in the hoist box.
(Note: Per TS 3.9.4 One SDC Cooling Loop shall be operable and in operation. The fact that B has no power and A is gas bound Condition A is not met and loading irradiated fuel must be suspended immediately)
Unit 1 is at 100% power.
Spent Fuel Pool (SFP) level is 137’10” and has been noted by the AO to be slowly losing level over the past several shifts.
Chemistry has just reported SFP Boron Concentration at 1900 ppm.
The crew is investigating the loss of level at this time.
You are directed by the CRS to add water to the SFP.
Which ONE of the following is the appropriate source of makeup water to the SFP?
A. Recycle Monitor Tank.
B. Refueling Water Tank.
C. Condensate Storage Tank.
D. Reactor Makeup Water Tank.
B. Refueling Water Tank.
Note: RWT is borated to >4400 ppm and is the correct source
Unit 3 is in a Refueling Outage.
The Containment LSRO is in process of loading a fuel bundle into the core.
The count rate on Startup Channel #1 increases by a factor of 5.
The count rate on Startup Channel #2 increases by a factor of 3.
No RMS alarms or trends are present in the Control Room.
Which ONE of the following is the correct required response to this event?
A. Withdraw the last inserted fuel assembly and observe Startup Channel response.
B. Stop all fuel movement and order an evacuation of non-essential personnel from containment.
C. Stop all fuel movement and initiate a CPIAS, Containment Purge Isolation Actuation Signal.
D. Fuel movement may continue provided that the Operability of Startup Channel #2 is confirmed.
A. Withdraw the last inserted fuel assembly and observe Startup Channel response.
PCA-P01 (Spent Fuel Pool Cooling Pump A) is operating on the Spent Fuel Pool.
A large break occurs in the discharge of the pump.
Which ONE of the following will prevent Spent Fuel Pool level from lowering to the point of uncovering fuel assemblies?
A. Excessive flow check valves will automatically close.
B. PCA-P01 (Spent Fuel Pool Cooling Pump A) will trip on high discharge flow.
C. PCA-P01 (Spent Fuel Pool Cooling Pump A) will trip on low suction pressure.
D. Fuel pool cooling suction piping will become uncovered by the lowering spent fuel pool level.
D. Fuel pool cooling suction piping will become uncovered by the lowering spent fuel pool level.
(Note: Fuel pool cooling suction piping is in the upper level of the SFP)