Rad Monitors/ODCM Flashcards

1
Q

RU-1, Containment atmosphere

A

LCO requires Particulate and Gas
Isolates on CIAS
Detects 1 gpm leak in 1 hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

RU-2/3 EW train A/B

A

Indicates RCS in-leakage if EW is crosstied to NC
RCP HPSC or SDC Hx

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

RU-4/5 Steam Generator blowdown sample lines

A

Isolated by SIAS, AFAS, MSIS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

RU-6 NC

A

Detects in-leakage from Letdown Hx or HPSCs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

RU-7 Aux Steam condensate tank

A

Re-aligns tank return to LRS (isolates path to the condenser)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

RU-12 Waste Gas Decay Tank

A

ODCM
Isolates tank release path on high beta activity
Should not detect a tank leak
Release allowed if:
-2 independent samples of the tanks are analyzed
-2 qualified members verify the calcs and valve lineup

Flow monitor failed: release may continue if the flow rate is estimated every 4 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

RU-18 Main Control Room

A

EAL Alert if > 15 mR/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

RU-19 New Fuel Area

A

TRM, if non functional, survey every 24 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

RU-29/30 MCR intake vents

A

3.3.9, actuates CREFAS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

RU-31 SFP Area

A

Actuates FBEVAS
Cross trips CREFAS
TRM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

RU-37/38 Containment Purge

A

Actuates CPIAS
Cross trips CREFAS
Purge area RU between power access purge and refueling purge exhaust ducts in aux building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

RU-139A/B
RU-140A/B
Main Steam Lines in MSSS

A

N-16 detectors
Used for SGTR diagnosis
Detects > 10 GPM leak
TRM-one required per SG

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

RU-141A/B Condenser vacuum/Gland seal exhaust

A

Channel 1 (a): aligns post filter blower unit. Alarms at 1 GPM with 1% failed fuel (1440 GPD)
Channel 2 (b): most sensitive for tube leakage. Alarms at 50 GPD because its not diluted by GS exhaust

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

RU-142 a/b/c/d Main Steam Lines N-16 monitors

A

Detects 30 GPD leak

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

RU-143/144 Plant Vent Low and High range

A

ODCM
Low range shuts off and hi range comes on (and vice versa) as level comes up
Estimate flow once every 4 hours
Initiate the pre-planned alternate sampling program
Place moveable air monitors in line
Grab samples every 12 hours if the monitor is functioning locally

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

RU-145 Fuel Building low range Gas

A

ODCM
Actuates FBEVAS and cross trips CREFAS

17
Q

RU-146 Fuel Building Vent Mid-hi range

A

ODCM

18
Q

RU-148/149 Containment Hi range

A

3.3.10 PAM
Used for Eplan
Used to determine harsh containment

19
Q

RU-150/151 next to each cold leg

A

3.3.10 PAM N-16 monitors
Monitors for fuel damage

20
Q

RU-155D Letdown line monitor

A

Unusual Event if in alarm
Indicates failed fuel
6 minute transit time