3.9 Flashcards

1
Q

3.9.1 Boron Concentration
M6

A

Boron concentration of the RCS and the refueling canal w/i COLR limits > 3000 ppmB

IMMEDIATELY
1. Suspend core alts
2. Suspend reactivity additions
3. Restore to within limit (borate > 26 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

3.9.2 2 Startup range NIs
M6

A

2 channels operable

OPERABLE = continuous visual indication in MCR
audible indication in both CTMT and MCR
- 1 inop: IMMEDIATELY suspend core alts and +Rx additions
- 2 inop: IMMEDIATELY take actions to restore

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

3.9.3 Containment Penetrations
During core alts and moving fuel in CTMT

A

Close within time to boil or < 30 minutes
Equipment hatch: closed w/4 or more bolts, or capable of being closed
Personnel hatch: at least one door capable of being closed

IMMEDIATELY suspend core alts and fuel movement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

3.9.4 SDC - High Water Level
M6 with > 23’ above the flange

A

1 SDC loop operable and in operation (> 3780 gpm)
May remove from operation < 1 hr per 8 hour period if no dilutions
Allows core mapping, fuel movement near HL nozzles, pump/valve testing

IMMEDIATELY stop core alts, stop any dilutions, restore SDC
4 hours close all containment penetrations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

3.9.5 SDC Low Water Level
M6 and < 23’ above the flange

A

2 SDC loops operable with one in operation
May remove from operation < 1 hr per 8 hour period if no dilutions
Allows core mapping, fuel movement near HL nozzles, pump/valve testing
One loop may be inop for < 2 hours for STs if the other loop is operable and in operation

1 loop inop: IMMEDIATELY restore SDC loop OR raise level to > 23’
2 loops inop: IMMEDIATELY initiate actions to restore, stop any dilutions
4 hours to close CTMT penetrations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

3.9.6 Refueling Water Level - Fuel Assemblies
During fuel movement in containment

A

> 23’ above the flange

IMMEDIATELY stop fuel movement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

3.9.7 Refueling Water Level - CEAs
During movement of CEAs within the vessel

A

> 23’ above the top of the seated fuel

IMMEDIATELY stop fuel movement
Retains Iodine during a fuel handling accident and limits offsite dose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

TLCO 3.9.100 Decay Time

A

Reactor subcritical > 100 hours prior to fuel movement
Allows for decay of short lived fission products

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

TLCO 3.9.101 Communications

A

Direct communications between MCR and refueling station during core alts
Verified within 1 hour prior to core alts, then every 12 hours

Immediately suspend core alts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

TLCO 3.9.102 Refueling Machine

A

Machine must be functional
1600 lb overload limit: checked within 72 hours of moving fuel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

3.9.103 Crane Travel - SFP building

A

Loads > 2000 prohibited over the assemblies in the pool
Crane has interlocks to prevent travel

Not met: place crane in a safe position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

TLCO 3.9.104 FBEVS
During movement of FAs in fuel building
RU 31/145

A

2 trains required to be functional

1 train non functional: IMMEDIATELY verify the functional train can be powered from a DG
Restore within 7 days
Time not met: place the functional train in service…or stop moving fuel

Both trains non functional: IMMEDIATELY stop moving fuel

If a roll up door is open, both trains are non functional.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly