3.7 Flashcards

1
Q

3.7.1 Main Steam Safety Valves

A

Modes 1,2,3
1-4 per SG INOP in M1/2 = reduce power and VOPT trip in 4 hours/36 hours
5-8 per SG INOP in M1/2 = M3 in 6
> 8 per SG INOP in any mode = M3 in 6 AND M4 in 12 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

3.7.1 Main Steam Safety Valves
Lift Settings

A

1 - 1250 psig
2 - 1290 psig
3 - 1315 psig
4 - 1315 psig
5 - 1315 psig
+/- 3%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

3.7.2 Main Steam Isolation Valves

LCO and applicability

A

M1
M2-4, except when all MSIVs are closed and deactivated

4 MSIVs and their associated actuator trains

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

3.7.2 Main Steam Isolation Valves

Conditions

A

1 MSIV INOP = 4 hours to restore
2 or more INOP = 1 hour to restore all but one
Time not met = M2 in 6 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly