Emergency Boration AOP Flashcards
Emergency Boration
Entry and Exit Criteria
Entry
- Loss of SDM
Or
- RCS Boron less than required for current plant conditions
Exit
- SDM recovered
- RCS Boron meets requirements for plant conditions
- entry into any EOP or LMFRP is required
Emergency Boration
Which pump to use?
Charging pump is first, if it is available
Then HPSI
Then LPSI
Emergency Boration
Which suction path to use?
Alternate CHP suction
When RWT level is less than 73%
APP B
All manual valves in the aux building
Emergency Boration
Which suction path to use?
Gravity Feed
Gravity Feed is through CHE-536
- no BAMPs
- CHV 501 is closed
Emergency Boration
Which flowpath to use?
Through CHN-514
A BAMP is available
CHN-536 is closed
You can still go through CHN-514 if a BAMP is not available, if:
- you can only run two CHPs
- you have to stop any fuel pool cleanup pumps
- you have to close CHN-501 and open its breaker