Loss Of Cooling Water AOP Flashcards

1
Q

Loss of Cooling Water
What are the RCP limitations without NC?

A

Only NC lost = Restore within 10 minutes
NC and Seal injection lost = Restore NC within 3 minutes
If time not met
- trip the Reactor
- Stop all RCPs
- isolate Seal Bleedoff

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Loss of cooling water
TCA to prevent RCP bearing seizure

A

30 minutes = Loss of NC, shutdown RCP and isolate cooling water
10 minutes = Loss of NC, cross tie EW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Loss of Cooling Water
Reason for seal Bleedoff isolation

A

When RCPs are stopped and have no cooling water, bleed off flow is no longer being cooled by NC, seal damage may result and cause a LOCA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Loss of Cooling Water
NC leak inside containment

A
  • Close NC CIVs
  • trip the reactor
  • trip RCPs
  • isolated seal Bleedoff
  • GO TO appropriate procedure
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Loss of cooling water
LCO impacts when EW is cross-tied to NC

A

LCO 3.7.7, EW
LCO 3.7.10, EC

Invoke LCO 3.0.6 and perform the SFDP
Declare SDC INOP and enter 3.4.6 and 3.5.201 if in the applicable MODE
Declare the following INOP, but do not enter the conditions or perform the required actions
- ECCS
- CS
- EW
- AFA
- CREATCS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly