Programming, Planning and Analysis 15% (Life Safety Codes/Standards) Flashcards

1
Q

Flammability Standards

NFPA 701

A

Vertical ignition test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Flammability Standards

NFPA 260

CAL TB 117

A

Cigarette ignition Resistance Test

separate fabric and fillings of upholstered furniture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Flammability Standards

NFPA 261

CAL TB 116

A

Cigarette ignition resistance test

seat cushion, foam, liner and fabric

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Flammability Standards

NFPA 266

CALTB 133

A

Full Seating Test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Flammability Standards

ASTM E84

A

Steiner Tunnel Test

Flame spread of interior finishes and building materials

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Flammability Standards

NFPA 258

ASTM E662

A

Smoke density chamber test
(tested in lab)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Flammability Standards

ASTM E119

A

Assembly test

Walls, strucures, ceilings and glazing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Flammability Standards

NFPA 251

A

Wall assembly test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Flammability Standards

NFPA 252

A

Door assembly test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Flammability Standards

NFPA 257

A

Window assembly test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Flammability Standards

NFPA 253

ASTM E648

A

Radiant Panel Test

Floor coverings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Flammability Standards

NFPA 265

A

Room corner test for textiles

Flame does not reach the ceiling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Flammability Standards

NFPA 286

A

Room corner test

Flame reaches to ceiling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Flammability Standards

ASTM D2859

A

Metenamine pill test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Flammability Standards

ASTM E2573

A

Prep and mounting for stretch fabrics

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Flammability Standards

Flammable

A

Capable of burning with a flame or igniting

17
Q

Flammability Standards

Flame resistance

A

Ability to withstand flame

18
Q

Flammability Standards

Fire Resistance

A

Properties of material or assembly to withstand fire

19
Q

Flammability Standards

Smoldering

A

Combustion without flame

20
Q

Toxicity and Indoor Air Quality

Three categories that toxicity of a building falls within

A
  • Chemcial
  • Biological
  • Physical
21
Q

Toxicity and Indoor Air Quality

4 cause of poor IAQ

A
  • Chemical contaminants from indoor
  • Chemical contaminants from outdoor
  • Biological Contaminants
  • Poor Ventilation
22
Q

Indoor Air Quality Standards (IAQ Standards)

Clean Air Act of 1970

A

Regulates air emissions from area, stationary, and mobile sources

23
Q

Toxicity and Indoor Air Quality

ANSI/ASHRAE Standard 62.1

A

Ventilation for acceptable IAQ

Sets minimum oudoor air requirements for vetilation

24
Q

Indoor Air Quality Standards (IAQ Standards)

National VOC Emission Standards

A

Sets limits on the nuber of VOCs that architectural coatings can have

25
Q

Indoor Air Quality Standards (IAQ Standards)

National Ambient Air Quality Standards

A

Limits on atmospheric concentration of six pollutants that cause smog, acid rain, and other health hazards

26
Q

Indoor Air Quality Standards (IAQ Standards)

ANSI/ASHRAE Standard 62.2

A

Ventilation for acceptable IAQ in low rise residential buildings

3 stories or less

27
Q

Indoor Air Quality Standards (IAQ Standards)

National VOC emission standards

A
28
Q

Indoor Air Quality Standards (IAQ Standards)

California Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65)

A

Prevents business from dumping chemcials into sources of drinking water

29
Q

Indoor Air Quality Standards (IAQ Standards)

Greenguard Environmental Institute

A

Give exposure limits for chemcials in the workplace

30
Q

Indoor Air Quality Standards (IAQ Standards)

ASTM E1333

A

Standard test method for determing formaldehyde concentrations in air and emisson rates from wood products

31
Q

Slip Resistance

ADA static COF for accessible routes

A

0.6

32
Q

Slip Resistance

ADA static COF for accessible ramps

A

0.8

33
Q

Slip Resistance

Min. slip resistance of a floors that are wet with water

A

0.42

34
Q

Slip Resistance

DCOF

A

Dynamic Coefficient of Friction

Less than COF for the same materials

35
Q

Accessibility and Egress Clearances

A
36
Q

What is ASTM’s Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials and is a test that measures smoke density in lab conditions in a smoke chamber – but cannot predict the density of smoke generated by the materials upon exposure to heat and flame under actual fire conditions?

A

NFPA 258 or ASTM E662