Pressurizer Pressure Control Flashcards
How many Pressurizer heaters do we have?
120 heaters total
12.5 kw/heater for a total of 1500 kw
How are Pressurizer heaters divided up into groups?
- 108 backup heaters divided into 4 groups. Groups 1 & 3 have 24 heaters (300 kw/group), and Groups 2 & 4 have 30 heaters (375 kw/group).
- 12 proportional heaters divided into 2 groups of 6.
How are the backup heaters normally operated?
Normally in manual (always on).
What are the advantages if having the backup heaters in manual?
- Eliminates cycling
- Allows for better pressure control
- Gives quicker spray response
- Provides better boron mixing
How are the proportional heaters controlled?
Controlled by Pressurizer pressure controller.
At what Pressurizer pressure controller output signal are the proportional heaters on and off?
- Full on at 0% output
- Off at 33.3% output
What is the Pressurizer low level cutout?
At 36% level in the Pressurizer, heater breakers trip to prevent the heaters from becoming uncovered, and CV-2003 closes to isolate letdown.
What is the function of the heater control selector switch?
Selects which Pressurizer level controller sends the low Pressurizer level cutout to heaters and CV-2003.
What are the switch positions for the heater control selector switch?
- A - only ‘A’ level controller sends signal
- B - only ‘B’ level controller sends signal
- A-B (normal) - both ‘A’ & ‘B’ send a signal. If either get a low level of 36%, it will send a signal to trip the heaters and close CV-2003.
How does a loss of Y-01 affect the Pressurizer pressure control system?
Causes a loss of protective function to trip heaters and close CV-2003 on 36% Pressurizer level.
What is the function of Pressurizer spray?
Uses continuous spray to reduce thermal shock of the spray nozzle and provides better mixing of boron in the Pressurizer. Spray flow comes from PCS cold legs, so it keeps Pressurizer boron concentration closer to PCS boron concentration, which prevents a reactivity event if an out-surge occurs.
Where does Pressurizer spray flow come from?
PCS cold legs loop 2A (C PCP), and loop 1B (B PCP)
How are the Pressurizer spray valves operated?
- Air to open, fail closed
- Controlled by the Pressurizer pressure controller
- Uses D/P between PCS and Pressurizer for motive force for spray flow
At what Pressurizer pressure controller output signal are the spray valves open and closed?
- Closed at 66.6% output signal
- Full open at 100% output signal
How does operating with only 1 PCP in each loop affect Pressurizer spray flow?
Maximum 40% total spray flow