PRD (API 576) Flashcards
1
Q
Weight-loaded Pressure-/Vacuum-relief Valve (3)
A
- These devices are used where operating pressures are very near atmospheric conditions.
- The set pressure or vacuum setting can be changed by adding or removing weights in the seating area of the valve.
- They are often used to satisfy the normal venting requirements caused by thermal inbreathing/outbreathing and product pump-in/pump-out effects.
2
Q
Pressure- and/or vacuum-vent valves Designed to what?
A
designed to vent air and vapor from the tank during filling operations and to admit air when the tank is drawn.
3
Q
PVRV are prone to what?
A
sticking (Periodic examination may detect this condition. )
4
Q
Where temperatures fall below freezing, what to be done?
A
the devices may need to be checked during the cold period to ensure that the discs (normally called pallets) do not stick because of icing.
5
Q
Recommended steps for inspection (9)
A
- The discs (normally called pallets) of the devices should be checked for sticking.
2 .If the mass is not correct, mass should be added or removed until the correct mass has been achieved. - The seats and pallets should be checked and cleaned
- The gaskets at the pallet seating areas should be checked and, if necessary, replaced
- The protective screens should be checked for serviceability and, if necessary, renewed.
6.If the weights are positioned on a moment arm attached to the seating area, then hinges and hinge pins should be checked for operability and, as necessary, serviced, lubricated, and replaced. - Any special coating used internally or externally on the body should be checked and, if unserviceable,
replaced. - The hood should be inspected and, if unserviceable, replaced.
- The bolts should be checked and, as required, replaced.