Asme V UT - (chap 13 / III E) Flashcards

1
Q

What is the UT limitations?

A

200F, and applicable to material that will propagate a constant velocity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What technique is used?

A

Pulse-echo

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Formula?

A

T=vt/2
T=thickness
v=velocity
t=transit time

velocity can be found in ASTM 494, instrument will obtain the transit time to calculate the material thickness.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How to verify effectivity of UT measurement?

A

Using 2 size of reference blocks,

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the display element?

A

A scan display, meter or digital displayer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the 4 items that need to be subject to contractual agreement?

A
  1. Personnel Qualification
  2. Qualification of NDE agencies
  3. Procedure and techniques
  4. Surface preparation
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the flaw detectors readouts?

A
  1. A scan display readouts -
  2. numeric readouts
  3. Thickness readouts
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is flaw detectors with A scan display readouts?

A

displayed in time/amplitude. Thickness determination are made by reading the distance between the zero corrected initial pulse and first returned echo (back reflection) or between multiple back reflection echoes on a STANDARDIZED BASED LINE.
Base line should be adjusted for the desired thickness increments

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is flaw detectors with numeric readouts?

A

combination of pulse ultrasound flaw detection instrument with A scan display and additional circuitry that provides digital thickness info.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is flaw detectors with thickness readout

A

modified version of pulse echo instrument. The elapse time between the initial pulse and first echo or between multiple echoes is converted into a meter or digital readout.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When do we use UT?

A
  • evaluation of tank shell for CR
  • evaluation of tank bottom (MFL is used with UT)
  • tank roof evaluation (if corroded to avg thickness of less than 0.09” in any 100in^2 area)
  • evaluation of thickness of components - like reinforcement plates, nozzle necks, cover plates.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly