API 653 Chap 7/8 Flashcards

1
Q

What test to perform if material has no identification? (2)

A
  1. mechanical tests (ASTM A6 )

2. Charpy V-notch (A370)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

All known material must meet what criteria?

A

chemical and mechanical properties in regards to thickness , design, and metal temperature in API 650 Figure 4.1a

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What happen when the direction of rolling is not known?

A

2 tension specimens shall be taken at right angles to each other from a corner of each plate, and one of those test specimen must meet the requirement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Existing rolled structural shape that are reused shall meet what requirement?

A

ASTM A7 (obsolete)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

New structural material shall meet what requirement?

A

ASTM A36 / A992

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Flanges / fasteners shall meet?

A

as built standards as a min/ current applicable standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What should new weld joint meet?

A

welding requirement of the current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What should existing weld joint meet?

A

requirement of the as built standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where should the allowable stress (and hydro) for reconstructed tank be taken from? and what if the material not listed?

A

API 650 table 5-2 , 2/3 Y and 2/5 T (lesser), 3/4 Y and 3/7 T for hydro

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Replacement/new penetration’s shall meet what?

A

Current standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Existing penetration shall meet what?

A

As built standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What should reconstructed tanks be checked for?

A

(1) wind induced buckling with current

(2) seismic stability with current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

windgirders shall meet?

A

current standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

roofs shall meet?

A

as built standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly