Performance Flashcards

1
Q

Basic Empty Weight:

A

All fixed equipment, system fluid, unusable fuel, configuration equipment including galley structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Basic weight + Crew+Pantry =

A

Dry Operating Weight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

On ECAM CAB PRESS page the cabin altitude indication

A

Changes from green to red when the cabin altitude is more than 9,550ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

With the guarded MAN VALVE SEL in the AFT position, the FWD valve remains

A

Under automatic control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

With DITCHING pb sw ON, outflow valves close automatically if

A

the pressurization system is under automatic control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Max positive differential pressure

A

9.25 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Max negative differential pressure

A

-0.73 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Safety relief valve setting

A

8.83 / - 0,26

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Max differential pressure and safety valve setting tolerance

A

+ - 7hPa (0,1 psi)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Max Neg delta P

A

-50 hPa (-0,73psi)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Outflow valve closure

A

15,000ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Max cabin alt selection

A

14,000ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Max alt

A

41,500ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Max normal cabin alt

A

8,000ft (less than 2,5h) and 7,460 ft (593hPa)(more than 2,5h)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Min cab alt selection =

A

-2,000ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Delta P = 574 hPa

A

8.32psi Max normal

17
Q

Delta P = 610 hPa

A

8.85psi safe valve setting

18
Q

Delta P = 638 hPa

A

9.25psi max overpressure