Oily Waste and Non-Radioactive Waste System Flashcards
What is the purpose of the OW system?
Collect and transport liquid waster from equipment and floor drains in the turbine building, control building, diesel building, fire pump house and yard area
collection point for an oil/water mixture at the oily waste separator where the oil is manually skimmed and removed for proper disposal
How many sump pumps are utilized in the sumps of the OW system?
2 each
What is the purpose of the alternator?
Swap lead pumps to equalize run time and wear
Why is there flow orifices installed in the discharge of the sump pumps?
to balance flow to control pump runout during one or two pump operation
What system provides lube to the control building sump pumps intermediate and case bearing?
Demin water (DW)
What system provides lube to the DG building sump pumps?
Domestic service (DS)
What starts and stops the sump pumps on high or low level?
Float level control switches (first set for control and second for alarm)
The turbine building OW system sump pumps normally send waste to oil/water separator. Where else can waste be sent?
CWNT or LRS holdup tanks if there are chemicals or radioactivity
Where is the water from the battery room in the switchgear building directed?
Acid neutralizing sump in the room and then to the north condenser sump
Generally what type of water is collected in the turbine building sumps?
Water with the highest potential for water being present
What waste is received in the North condenser area sump?
North and west areas of the turbine building and the CST pump house
What drains are collected in the West control building sump?
‘A’ train side of the control building
‘A’ & ‘B’ EW heat exchanger tube side drains
What drains are collected in the East control building sump?
‘B’ train side of the control building
What is different about the waste from the ‘A’ and ‘B’ cable spreading rooms?
They do not flow to the control building sumps
They drain separately to the ground outside the control building
Drain screens on the outlets of the 2 drains
What collects in the east and west diesel building sumps?
Their respective diesel leakage