Feedwater/Feed Pump Turbine System Flashcards

1
Q

What is the purpose of the FW system?

A

Supply feedwater from the suction of the FW pumps to the feedwater regulating valves in the line to each S/G at the required pressure, temp and flow rate.
provide the final 3 stages of feedwater heating in two parallel heater trains.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the purpose of the MFWPs?

A

Provide motive force to raise the pressure of the supplied condensate from around 350psig to around 1200 psig to overcome the S/G pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

what type of impellers are utilized on the MFWPs?

A

Double suction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What system provides lube oil for the bearings on the MFWPs?

A

Steam generator feedwater pump turbine lube oil system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What capacity are each of the feed pumps designed to handle rated power? what is the procedural limit?

A

65% of the total required flow.
Procedurally limited to 62% during a downpower to remove one FWP from service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What pressure does the seal water enter the feed pump casing form the gland seal regulator?

A

150psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where does this seal water come from?

A

Condensate service header

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

what is the purpose of the 2, 2.5 inch “Y” strainers in the seal water lines?
how many are normally in service?

A

to protect FWP seals from damage due to solids.
1 in service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What D/P is normally maintained across the seals by the gland seal regulators?

A

15psid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What output pressure do the gland leak off regulators maintain?

A

135psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

how much air pressure is utilized in the new inpro seals?

A

1 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the purpose of the mini flow valves?

A

To open or close as feedwater flow changes to maintain approx 5000gpm thru the MFWP to prevent overheating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

why does the mini flow valve shut when the MFWP trips?

A

to prevent the pump from freewheeling due to condensate system flow thru the mini flow valve to the condenser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When would the mini flow valve fully open?

A

When the pump discharge valve is fully shut

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How do the mini flow valves fail on loss of IA?

A

full open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

the mini flow valves use how many air boosters for positioning?

A

2, one for opening and one for shutting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

what happens to the mini flow valve when feed pump turbine lube oil pressure drops below 75 psig? why?

A

Go closed to prevent pump from freewheeling due to feedwater flowing thru an idle pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

how are the mini flow valves affected by a loss of 120VAC?

A

Fails open. if the FWPT trips or is already tripped the valve will close due to the energization of the DC solenoid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

how are the mini flow valves affected by loss of 125 VDC?

A

Normal ops, no effect.
If FWPT is tripped, a loss of DC will result in the valve failing open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

How often is the HP stop valve tested? any precations?

A

Daily.(Weekly) look this up!
HP control valve must be closed before testing the stop valve.
There is an interlock which prevents testing the HP stop valve if the HP control valve is open.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

HP and LP control valves are operated by one hydraulic cylinder. Due to mechanical arrangement which valve opens first?

A

LP control valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the difference between the HP and LP stop valves concerning design features?

A

LP stop valve has its own valve body and when testing the LP stop valve it only goes half way closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Why is there a pressure switch installed on the control oil pressure line?

A

Acts to close the turbine control valves whenever the FWPT is tripped.
This prevents an uncontrolled start which could occur since on turbine reset the LP and HP stop valves immediately go wide open

24
Q

what controls the speed of the FWPT?

A

Main feedwater control system

25
What system is the Feedwater control system part of?
Reactor control system
26
What are the 2 normal sources of steam to the feed pump turbines?
main steam and reheat steam from the MT system MSRs
27
What is the 3rd source of steam for the MFPTs?
Aux steam
28
what is the flow path for the MSR reheater to the feed pump?
Flow thru the low pressure stop valve and low pressure control valve. 'D' MSR
29
What is the flow path for the main steam to the feed pump?
flows thru the high pressure stop valve and high pressure control valve
30
What is the normal source of steam?
low pressure reheat
31
When would we use high pressure steam in MFWP?
During startup and to supplement the low pressure system during periods of light MT loads or overload on the FWPT
32
When would we use AS for feed pumps?
Testing
33
What ultimately controls the stop and control valves?
FWPT control oil
34
what system provides shaft sealing steam to A and B FWPTs?
Turbine steam seal and drain system (GS)
35
What cools the feed pump oil system?
NC
36
Where do the FWPTs exhaust to?
'A' and 'B' condenser reheat trays and into the 'c' condenser
37
Where are the FWPT drains directed to?
'A' and 'B' condenser sections
38
how many wheels make up the feed pump turbine?
6
39
Where are the thrust wear trip and overspeed trip governors located?
HP end of the rotor and are part of the rotor assembly
40
where is the engagement gear for the turning gear located?
exhaust end of the rotor
41
What is the normal position of the turbine drain valves under full steam load?
normally closed
42
If the turbine drain valves are closed, how do we remove condensate during normal ops?
They are provided with a continuous bypass drain line thru an orifice
43
What is the purpose of the feed pump turning gear?
to provide low speed turning of the rotor for cooling or heating up to prevent warping
44
What is the interlock associated with the feed pump turning gear and what is it trying to prevent?
2 pressure switches, 1 monitioring oil pressure on the feedwater pump bearings and the other monitor the oil pressure to the turbine bearings. a low pressure in either switch will prevent the turning gear motor from operating. This interlock is for bearing protection.
45
Where is the feed pump turning gear normally operated from?
control room
46
What are the various FWPT trips?
1)Turbine bearing low oil pressure 2)Pump bearing low oil pressure 3)Exhaust vacuum low 4)Feedwater pump suction pressure low 5)Feedwater pump discharge pressure high 6)Thrust bearing wear high
47
What are the three feedwater turbine thrust bearing test switches?
Thrust wear device test switch Active thrust wear test switch Inactive thrust wear switch
48
What nominal set point is the mechanical overspeed trip tested to?
110%
49
What is another way to test out the overspeed without getting up to that speed setpoint?
A jet of oil, controlled by a solenoid valve, can be sprayed into the emergency governor housing to unbalance the plunger and actuate the emergency trip at speeds up to rated
50
During a startup, when is the first main feed pump started?
Prior to exceeding a reactor power of 3% which is the capacity of 1 AFP
51
When is the 2nd MFWP started?
50% power
52
Prior to startup what must be done with the Condensate/feedwater systems to improve the water quality?
Long path recirc
53
During normal operation when can i secure one of the FWPs?
If plant load decreases below 62%
54
What is meant by "Standby" when referring to the MFWPs?
The pump and turbine are in a warmed and ready condition
55
After each shutdown, why is the main feedwater system placed in long path recirc?
For shutdown chemistry control and system cooldown
56
What will happen if i lose a feedwater pump while at 100% power?
Reactor power cutback, lowering reactor power and turbine power to within capacity of a single main feedwater pump
57
What will happen if we lose a FWP while at 100% power?
Reactor would trip on low S/G level. S/G level would have to be maintained by aux feed system