Extraction steam and Drain System Flashcards

1
Q

What is the purpose of the ED system?

A

Preheats condensate and feedwater prior to entering the steam generators to increase overall plant efficiency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What system has the ability to provide steam to the 4th point heater during startup?

A

Aux steam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What system is used to add cool water to the water volume that is maintained in the bottom of the blowdown stack?

A

DS domestic service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the purpose of the blow down stack?

A

A collection point for steam traps, HP heater relief valves and Misc aux steam drains

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When is DS added to the blowdown stack? What if DS is not available?

A

When temp of the blowdown stack exceeds 150F

If not available there will be steam coming out of the blowdown stack and the north condenser sump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

how does GA interact with ED?

A

Supplies nitrogen for steam blanketing when shut down to prevent corrosion

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How does IA interact with ED?

A

MT control system admits IA thru both critical and non critical relay dump valves which provide a signal to the bleeder trip valves

Also provides motive force for all AOVs in ED system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

how are the BTVs affected by a loss of IA?

A

They lose open permissive and go partially closed. They stay open due to ED steam flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where are the Heater drain pumps powered from?

A

‘A’ NBN-S02 AND ‘B’ NBN-S01

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where does the seal water for each heater drain pump come from?

A

Directly from the condensate header at 375-500 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What provides cooling to each heater drain pump stuffing box?

A

Condensate service header at 50-100psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What positions the heater drain pump mini flow valves?

A

Heater drain pump flow transmitter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What 3 signals would stop the heater drain pump?

A

Heater drain tank lo-lo level
Heater drain pump low flow after a time delay
Electrical protection signal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Why does the #5 heater not have a level control system?

A

It drains directly to the heater drain tank and does not have a drain cooler region

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which LPFW heaters have 4 inlets?

A

1 and 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

which LPFW heater has an input from the S/G blowdown system?

A

3

17
Q

What is the purpose of the BTVs?

A

To prevent reverse steam flow when the turbine trips and prevent turbine overspeed

18
Q

What is installed on the BTVs to assist in opening the disc with a minimum differential steam pressure?

A

Balance arm device

19
Q

What happens upon activation of the BTV test valve?

A

Valve equalizes the air pressure across the operator piston to allow partial closing of the valve disc by spring force

20
Q

why is there 2 BTVs on the #4 LPFW heater?

A

4 has enough energy to overspeed the turbine

21
Q

Which control valves are reverse acting?

A

All the valves that dump to the condenser (all high levels and #1 LPFW heater normal)

22
Q

what air pressure are the reverse acting valves full open and full closed?

A

Full open at 3psig
Full closed at 15psig

(Normals) full closed 3 psig and full open 15psig

23
Q

What happens upon a hi-hi signal in a HP heater?

A

Extraction steam isolated

Close the normal level control valves of the preceding heater

opens the affected heaters motor operated extraction steam drain line

The 1st and 2nd stage drain tanks will vent to the condenser also

24
Q

What power level may there be insufficient D/P between the heater shells to allow for proper operation of the normal level control valves?

A

20%

25
Q

When is the first heater drain pump started?

A

25% power

26
Q

when is the 2nd heater drain pump started?

A

30-40%

27
Q

During plant shutdown when are the heater drain pumps secured?

A

First one at 40% and the second at 25%

28
Q

How is the ED system affected by loss of IA?

A

Heater drain pump discharge valve fails closed, recirc valve fails open, putting the pump on recirc.

Heater drain tank, MSR drain tank and 1st and 2nd stage reheater drain tank and feedwater heater high level dump valves all fail open and the normals fail closed except for the #1 heater

Heater drain pump will eventually trip on low flow or heater drain tank lo lo signals

The main steam supply to the 2nd stage reheater will isolate and the 1st and 2nd stage reheater drain tanks and tube bundles will vent to the condenser instead of their respective feedwater heaters