Feedwater Pump/Turbine Lube Oil System Flashcards

1
Q

What is the purpose of the FWP/Turbine lube oil system?

A

Provides lube oil to the bearings of the FWP and turbine.
Supplies control oil to the FWP turbine control system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

MFWP lube oil pump, which stage provides low pressure oil to supply the FW pump and turbine bearing headers?
What does the 4th stage provide?

A

First stage.
Higher pressure discharge used to supply the FW turbine control oil header

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What provides the cooling medium to the FP lube oil system

A

TC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What pressure is maintained in the LP oil header?

A

55psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What happens if we lose AC power to the oil pumps?

A

Emergency pump discharges directly into the pump and turbine bearing oil supply lines, bypassing the oil coolers and filters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the regulators for the bearing headers set at?

A

12psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What powers the MFW main oil pumps?

A

NH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What powers the vapor extractor blowers?

A

NH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What does NK power in the FW lube oil system?

A

MFW emergency oil pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What system purifies the feed pump lube oil and transfers lube oil to and from the reservoir?

A

Lube oil storage, transfer and purification system (LOST)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the capacity of the FW pump oil reservoir?

A

1000gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where is the the lube oil reservoir located?

A

Front of the turbine and extends under the governor casing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

where are the FWP/turbine main oil pumps located?

A

mounted in the reservoir with the motors on the reservoir

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the pressure of the low pressure discharge?

A

60-65psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the pressure reduced to for the bearings?

A

12psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the pressure of the high pressure discharge?

A

220psig

17
Q

under normal operations, how many lube oil pumps are running?

A

1 running and 1 in standby

18
Q

When would the standby lube oil pump start?

A

Low oil header pressure of 195psig (high pressure oil header is the one monitored)

19
Q

what is the purpose of the TEST push button for the lube oil pumps and where is that switch normally operated?

A

to test the auto start feature of the main lube oil pumps.
normally done from the control room

20
Q

What is the discharge pressure of the emergency lube oil pump?

A

12psig

21
Q

when will the emergency lube oil pump auto start? what is it meant for?

A

Upon receipt of a pump and turbine bearing low oil pressure of 37 psig.
only provides lube for coast down since it doesnt supply control oil or the trip headers

22
Q

Where are the lube oil coolers located?

A

110’ turbine bearing at the end of the feed pumps

23
Q

where are the vapor extractors located?

A

140’ turbine building

24
Q

What is the purpose of the vapor extractors?

what else does the vapor extractors do?

A

to create negative pressure in the oil reservoir, which will cause an inward flow of air thru the bearing oil deflectors in the bearing housing that will eliminate leakage of oil out thru the oil deflectors.

They also remove explosive gasses and air moisture in the MFWP oil reservoir

25
Q

What would be the adverse effect of too much vacuum in the lube oil reservoir?

A

can draw contaminates into the system and oil out the vent line

26
Q

What would be the adverse effect of losing feedwater pump/turbine lube oil?

A

One feed pump, results in reactor cutback
Two feed pumps result in reactor trip and aux feed will be used to fill the S/Gs

27
Q

How is the system affected by a loss of TC?

A

If lost for an extended period of time, the plant will have to be shut down and the feed water pumps stopped.