Aux Steam Flashcards
Why should we send aux steam to the MSRs
To establish a steam blanket while the main turbine is offline
Under normal conditions when should I use AS to provide GS to MT and MFWPs?
During a unit startup
The AS system can provide overspeed testing for what components?
Main feedwater pumps and ‘A’ AFP
Normally, main steam provides steam to the AS system. During a shutdown or startup where else may it be supplied from?
Another unit
what is typically main steam pressure and what does it get reduced to for use in the AS system
1000-1150 psig and reduced to 250psig
what pressure do the AS reliefs lift?
275 psig
AS pressure is further reduced to 50psig for use in what components?
Gas stripper, BAC, Evaporator
What pressure is AS used for steam blanketing in the MSRs?
52.3 psig
What does RU-7 monitor?
AS condensate receiver tank
What does NH power in the AS system? what happens if we lost NH?
Condensate transfer pumps
AS in aux building will be secured until power is restored and Gas stripper, BAC and evaporator cannot process
What does NC do for the AS system and what happens if it is lost?
Cools AS vent condenser and AS will need to be secured in the aux building
How is AS affected by a loss of rad monitoring?
condensate will need to be sampled before it can be sent to the main condenser
If AS system condensate drains are contaminated where are they sent?
LRS
Why do we establish steam blanket in the MSRs during shutdown?
To minimize corrosion and keep the tubes from moisture and oxygen
What is the condensate receiver volume and operating pressure?
335 gallons
50 psig