NEM Chapter 077, Safety Flashcards
All walk-in reefer boxes, lockers, freezers and chill spaces on cutters shall have door latches and locks that can be ___
Opened by a release mechanism located inside the space
All reefer spaces shall be outfitted with an ___ that can be manually actuated a individual locked inside
Electrical alarm system
The alarm system for walk in reefers shall consist of ___
An electrical switch in each reefer space and two alarm bells with red lens lamp indicators. One will be located on the mess deck, and the other outside the entrance to the reefer spaces
The alarm switch in the reefer must be ___
Mounted on the bulkhead by the door, and labeled “ALARM SWITCH - PERSON LOCKED IN REEFER”
The alarm bell with lamp indicator for the reefer alarm must be ___
Bulkhead mounted with a sign reading “PERSON LOCKED IN REEFER”
In addition to removing water and oily waste from a space, the suction created by the eductor can also remove ___, creating a risk of ___
Air supply
Asphyxiation
___ can cause an eductor to flood the space
Improper valve alignment and insufficient firemain pressure
A ___ volt safety shorting probe shall be conspicuously located in all engineering space containing switchboards or other installed high-voltage equipment
25000
___ shall be used to assess the electrical integrity of workshops
Electronics Manual, COMDTINST M10550.25
Diesel fuel may be used as a solvent onboard cutters if ___
Keep away from heat or open flame Provide adequate ventilation Wear rubber gloves Wear goggles Skin contact with fuel should be promptly washed Dont atomize the fuel
Wear ___ when handling hydraulic fluid or working on hydraulic equipment
Goggles, gloves, etc
Hot surface for F/O
400 degrees F (205 degrees C)
Hot surface for L/O or hydraulic fluid
650 degrees F (343 Degrees C)
For insulated surfaces, the temperature ___ is the reference temperature
Under the insulation
Place where the watchstander stands or the position from which they shift a duplex strainer
Normal operating station
Only acceptable cover material for duplex strainers
Sheet metal
Simplex strainer/filter spray shield shall be constructed of ___ or ___
Sheet metal held in place by the cover bolts
Cap of three layers of aluminized glass cloth secured with a drawstring
Smoke detectors must operate on a ___ and have a ___ audible low-voltage alarm
9 volt battery
30-day
At a minimum, one smoke detector shall be mounted to the overhead of living and berthing spaces that have a capacity of ___
1 to 10 people
Spaces having a capacity of ___ shall have no less than two smoke detectors
11 to 20 people
Spaces that have a capacity of ___ shall have no less than 3 smoke detectors
21 to 30 people
___ smoke detector is required for passageways that serve a living or berthing space
One
Gasoline fuel systems shall be adequately bonded to a ___ on the engine bed
Common ground
Gasoline fuel system bond straps or wires shall be ___
Braided and not less than No. 6 AWG
Gasoline fuel lines shall meet ___ and ___ specifications
SAE J1527
33 CFR 183
Gasoline fuel hoses shall be prominently marked as ___
USCG TYPE A2
USCG TYPE B1
USCG TYPE B2
The number of gasoline fuel system fittings shall be kept to an ___
Absolute minimum
Gasoline fuel lines for portable fuel systems shall be ___
Flexible so that they don’t crack, check, or break
Gasoline fuel quick disconnect fittings must ___
Automatically shut off fuel flow
Gasoline fuel system components, such as filters, shall be ___
Independently supported
___ shall be installed at the gasoline fuel tank outlet
Plug cock or diaphragm fuel shut off valves
___ shall be installed at the gasoline tank outlet close to the shut off valve
Anti-siphoning check valves
Battery storage compartments shall be ___
Ventilated to reduce the buildup of gasses
Electrical wiring in gasoline fuel systems shall contain no ___
Splices
Terminal connections in gasoline fuel systems shall be made with ___
Lugs or eyelets
___ shall be used to secure battery cables to battery terminals and lugs
Hex nuts and lock washers
___ shall not be used to secure battery cables to battery terminals and lugs
WIng nuts
In gasoline boats, high tension leads in the ignition system must be carefully checked for proper ___
Insulation
In gasoline boats, vent blowers should take suction ___
As low in the machinery space bilge as possible
In gasoline boats, only ___ vent blowers should be used
Explosion proof
In gasoline boats, suction hoses for vent blowers shall be ___
Wire-reinforced and arranged so that they do not become crimped
In gasoline boats, vent blowers must be operated ___
5 minutes before starting, during operation, and whenever fuel vapors are suspected or known to be pocketed in the bilges
___ shall not be permitted on gasoline boats
Smoking
In gasoline boats, bilges should be inspected ___
Daily and before operation
Portable F/O tanks/containers shall be inspected ___
Semi-annually
Every ___. installed gasoline fuel tanks shall be cleaned, flushed, and inspected
2 years
All personnel contemplating hot work on gasoline powered small boats shall review ___
SFLC GFE diagrams Tech pub 4622 for Defender class boats
Identifies the red, and green safety zones on boats
SFLC GFE diagrams