Module 26 Flashcards
Quality Assurance in Radiology includes??
Monitoring machines
storage of film
darkroom equipment
chair-side technique
What are the 6 steps of QA radiology programs?
chair side competence current technique charts maintain equipment maintain darkroom equipment maintain protective devices (cassettes) Proper handling and storage of film
DARK ROOM:
Daily you should ____ work area, check condition of _______ and check _____ and ______ of processing solutions?
clean
film holders
level
strength
DARK ROOM:
Monthly you should check for _____, ______ and accuracy of ______
light leaks
safelights
timer/thermometer
The coin test for the safelight:
Allow coin to be exposed on film for _____ min. under safelight….. if no image is seen on the film when processed you have a _____ safelight?
3min
good
Step Wedge test for processing solutions:
Expose _______ films all at one time?
The first film is a _____ film?
Then develop _____ a day and compare?
Densities will appear ____ if developer solution is weak.
pre-determined amount
reference
1 film
less dense/lighter
Fresh (unexposed) film will be developed and have a ___ color?
clear
______ ______ is one of the most critical areas in QA and requires daily monitoring?
Film Processing