Missed Questions - Balance & Interchange Flashcards
Each BA or RSG must review its contingencies on a \_\_\_\_\_ basis: A. Quarterly B. Annual C. As req'd by NERC D. Semi-annually
B. Annual
Each BA shall plan to be able to meet daily load patterns and changes in \_\_\_\_\_\_\_: A. Market requirements B. System load characteristics C. ATC D. Reserve sharing requirements
B. System load characteristics
In order for a generator to qualify as regulating reserve it must have which of the following characteristics?
A. Must be synchronized and its governor not blocked
B. Must be off-line and avail in 10 min
C. Must be synch’d and governor blocked
D. Must be 100MW and synch’d
A. Must be synchronized and its governor not blocked
If a BA has on-peak inadvertent accumulation of -350 MW, which of the following entities could a bilateral payback be arranged with? A. on-peak of -400 MW B. off-peak of +300 MW C. off-peak of -500 MW D. on-peak of +250
D. On-peak of +250 MW
Each BA is required to have enough operating reserves to meet which of the following? A. 150% of regulating requirement B. Loss of multiple contingencies C. DCS D. Regional black start margin
C. DCS
A BA's accumulated inadvertent is required to be accounted for on all of the following basis except: A. Hourly B. Daily C. Weekly D. Monthly
C. Weekly
If interchange transactions have been curtailed due to system congestion and the congestion has been cleared, what course of action should the system operator take?
A. Allow the transactions to re-start
B. Cancel transactions for the remainder of the day
C. Wait for someone to contact you
D. Request a waiver from NERC
A. Allow the transactions to re-start
Only certain entities can make a modification to a transaction tag for reliability related issues. Of the ones listed below, who is NOT? A. Load balancing area B. Transmission provider C. Load serving entity D. Generation balancing area
C. Load serving entity
Who is responsible for assessing the transaction start and end time, energy profile, and scheduling path on a tag? A. Transmission provider B. PSEs C. BA D. RC
C. BA
Who is responsible for assessing the loss accounting, proper transmission priority, and energy profile accommodation on a tag. A. PSEs B. Transmission providers C. BA D. RC
B. Transmission providers
Interchange transaction tags may be modified for market-related issues at what time?
A. While the tag is in progress or scheduled to be started
B. Only before implementation
C. Tags cannot be modified for market-related issues.
D. Only when the market operator agrees
C. Tags cannot be modified for market-related issues.