LOT 203.14 GWPS Flashcards
- LOT 203.14 GWPS*
- *
Where are the GWPS components physically located?
MAB 10’
Controlled from Radwaste Control Panel
- LOT 203.14 GWPS*
- *
What will auto shutdown the GWPS?
Boron Recycle Holdup Vent Pressure - Low
Bellows Compressor Leak
Inlet Pressure - High
System Flow - High
- *Room H2 - High (4)**
- 87.5% of lower flammability limit*
- *O2 - High**
- 20% of scale (1%)*
- *Outlet Radiation - High (RT-8032)**
- Adjacent-to-line gamma scintillation detector*
Closes system inlet (FV-4657), outlet (FV-4671), Boron recycle tank vent (FV-4651), and secures bellows compressor.
- Note:*
- Two radiation detectors in system (RT-8031/8032). Only RT-8032 will shutdown system.*
- LOT 203.14 GWPS*
- *
When starting up the GWPS, how long must the system be purged?
- System breach for Calibration/Replacement of O2 sensor:*
- *≥ 2 hrs**
- System breach for High O2 or Extended shutdown:*
- *≥ 16 hrs**
- LOT 203.14 GWPS*
- *
What is the GWPS O2 limit IAW TRM 3.11.2.5 Explosive Gas Mixture?
3%
TRM 3.11.2.5 Explosive Gas Limit
Applicability: At all times
Placing inlet (FV-4657) OR outlet (FV-4671) handswitches in OPEN causes O2 sensor to become inoperable.
- Note:*
- 0%-5% range normally selected because system trip will occur at 20% of scale (1%).
- If 0%-25% range selected, trip would be 5% (Above TRM limit)
- LOT 203.14 GWPS*
- *
What is a good DF value for the GWPS beds?
≥ 100
Inlet Activity/Outlet Activity
- LOT 203.14 GWPS*
- *
What are the influents to the GWPS?
Low pressure N2
PRT
RCDT
LWPS Waste Evaporator
BRS Recycle Evaporator
BRS Recycle Holdup Tanks
VCT
Rx Head Degassing Tank
- LOT 203.14 GWPS*
- *
What are the principle isotopes of concern for the GWPS?
Kr-85
Xe-133
- LOT 203.14 GWPS*
- *
What is the max temperature allowed for a GWPS charcoal bed?
85 ˚F
Requires one MAB supply and exhaust fan operating