LOT 202.02 Main Steam Flashcards

1
Q
  • LOT 202.02 Main Steam*
    • *

Which steam lines go to which steam chest?

A

“A” / “D” connect to West steam chest

“B” / “C” connect to East steam chest

Connect to equalizing header before going to main turbine.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • LOT 202.02 Main Steam*
    • *

Where does AFW #14 tap off the Main Steam system?

A

SG “D” PORV line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • LOT 202.02 Main Steam*
    • *

What are the design operating parameters of the Main steam system?

A
  • Pressure:*
  • *1285 psig**
  • 1185 psig - 1050 psig (0% - 100%)*
  • Temperature:*
  • *600 ˚F**
  • Saturated System (Dependent on pressure)*
  • Flow:*
  • *17,431,819 lbm/hr**
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  • LOT 202.02 Main Steam*
    • *

What is steam line equalizing pressure (PT-557) used for?

A

SGFPT control

  • *Steam Dumps**
  • When in pressure control mode*

Located on CP007

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • LOT 202.02 Main Steam*
    • *

What loads are supplied from the MS header?

A

MSRs (2)

Steam Dumps (12)

SGFPTs (3)

Gland Seal

Aux Steam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • LOT 202.02 Main Steam*
    • *

A loss of power to what components will cause the SG PORVs to close?

A

Hydraulic Pump:
ESF MCCs
Train A: SG “A” and SG “D” / Train B: SG “B” / Train C: SG “C”
Can be bypassed using station blackout switches
Once bypassed, can operate PORVs with accumulator pressure (1.5 strokes)

  • Servo Motors:*
  • *PORV “A”: DP1201**

PORV “B”: DP1203

PORV “C”: DP1204

PORV “D”: DP1202

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • LOT 202.02 Main Steam*
    • *

How is the MSIVs operated?

A

Air Open / Spring Close

  • Closes in ≤ 5 sec upon receipt of close signal
  • Both MSIVs and MSIBs fail closed on loss of air
  • MSIVs stay open on loss of power
  • Note:*
  • Physically located on IVC 58’
  • Controlled from CP006
How well did you know this?
1
Not at all
2
3
4
5
Perfectly