Important Secondary Shit Flashcards
How do the starting air valves fail due to a loss of CA on the EDG?
As Is
What happens if the EDG electronic governor fails High?
Speed will rise until the mechanical governor takes over
What are the 1KV Inverter loads for the EDG?
Speed Transmitters
Bear Temp Monitor
Field Flash Power
Local/Remote control Transfer Relays
Why is the EDG INOP during surveillance testing?
It will not generate a Loadshed signal
How will the EDG Throttle control cylinder fail on loss of CA?
Extended, forcing the fuel racks closed
What order do the EDG fans start on an EDG start?
Exhaust fan starts immediately
Supply fan has a 20 sec delay
What stops the EDG Ventilation fans?
30 mins after EDG stops
70*F Room Temp
CO2 Actuation
What supplies the EDG with fuel oil during operation?
Shaft driven pump
When do the upper valve gear lube oil valves open for the EDG?
On the start signal
2 mins every 4 hrs in Sby
When does the EDG Jacket water pump start?
on run relay (95% speed)
What are the Circ Water support systems?
250 VDC
MSCW
Screen Wash
Vac Priming
Does the CW Pump discharge valve change position automatically?
Only on an auto start or breaker opening
Manual starts require manual valve manipulations
What is the De-Icing flowpath?
WMO-16 or 26 Open
WMO-30 Closed
Can a NESW Pump be restarted after a loadshed?
Yes, by going to lockout after 75 secs
If you lose CA, do MAC valves has backup air bottles?
No
They close immediately
What are the suction sources for the NESW Pump in order of preference?
- Circ Water Suction (own and opp)
2. Discharge Tunnels (own and opp)
Where does CA come from to the ESW Strainers for backwash?
Unit 1 supplies both Units
Is there auto makeup to the CCW Surge Tank?
No auto signal
What is the makeup to the CCW Surge Tank?
Demin Water
What are the ESF Loads for CCW?
RHR hx RHR pp Seal Hx CTS pp Seal Hx SI pp Seal Hx SI LO cooler CCP LO cooler CCP Speed Increaser
What is the biggest Misc Hdr load for CCW?
SFP Hx
What are the pressures for compressed air system actions?
97# PAC Opp Unit PAC starts
90# CAC Starts
85# PA Hdr Iso Valve Close
80# Manual Rx Trip
Where is the 90# sensed to start the CAC?
wet air receiver pressure
PAC air flowpath for control air?
Pac ==> Plant Air Receivers ==> Control Air
Can the Backup PAC supply both units?
YES! If Isolation valves are closed
If you lose air to VRV-315/325 for the CR Ventilation, how will these valves fail?
Full flow to chillers
How much exhaust hood spray is there for U1?
138 gpm
How much exhaust hood spray is there for U2?
1200 gpm
What is minimum flow for a CBP?
4000 gpm
LP#1 heaters can provide how much flow capacity?
50% per string
LP 2-4 Htrs can provide how much flow capacity?
80% per string
CRV-224, LP Htr Bypass valve is good for how much flow?
20%
What is the purpose of CRV-224, LP Htr Bypass valve?
maintains NPSH for MFP
What are the loads for the TACW Pump?
Bus Duct Cooling
Hydrogen Coolers
Stator Water Coolers
Exciter Coolers
U1- Steam Packing Exhauster
U2- Glad Steam Condenser
Where does TACW system tap off of the condensate system?
between hotwell pump discharge and XS Flow Line to CST
TACW in closed cycle does what to efficiency?
lowers
TACW in open cycle does what to efficiency?
raises
What cools the TACW Hx?
Circ Water
What is the normal water source for the MFP seal water pump?
CBP Discharge
What is the purpose of the MFP Seal water FRV?
maintains seal water leak off temp at 150*F
What is the MFPT motive force below ~ 60% power?
Main Steam
What is the MFPT motive force at full power?
Reheat Steam
What is the preferred order of water supplies to the AFPs?
CST
Opp Unit CST
Condensate Hotwells
ESW
What does density compensation do for us in SGWLC?
Converts volumetric flowrate of steam to mass flowrate for input into the circuit
What causes SG Shrink? And where is the level measured?
reduction in steam flow, increase in SG pressure
Seen in the downcomer
What causes SG Swell? And where is the level measured?
Increase in steam flow, lowering of SG Pressure
Seen in the downcomer
What is the purpose of the SG PORVS?
Prevents lifting safeties to cooldown when dumps aren’t available
How much steam flow is a PORV good for?
2.5%
What is the setpoint for the SG PORV?
Adjustable
Normal is 1025#
What are the SG Safety set points?
2 @ 1065#
2 @ 1075#
1 @ 1085#
How much steam flow are SG safeties good for?
5.5% each
110% total
Can you close the SG Dump valves after a SLI?
Yes, take switch to lockout to prevent a release
How do the SGSVs fail on a loss of power to the dump valves?
Dump fails closed
SGSV stays open
How do the SGSVs fail on a loss of air to the dump valves?
Dump fails open
SGSV closes
Where are the rad monitors located for the SG monitoring system?
Downstream of PORVS
Is the rad monitor Operable if the PORV is isolated?
NO
Where do the reheater coil drains go?
6 heaters
Where do the Moisture separator drains go?
U1 5 heaters
U2 4 heaters
Do the #6 heaters have alternate drains?
NO
Do the # 4 heaters have alternate drains?
NO
What are the purpose of bleed steam check valves?
prevent turbine overspeed
What is the only manual trip for Stator Cooling Water?
High conductivity at 18 mmhos
What should the temperature be of Stator water in comparison to hydrogen gas?
water is warmer
3-4* C warmer
What is the auto makeup for SCW?
Demin Water
What is the heat sink for SCW?
TACW
What will a loss of CCRP-3 do to SCW?
Blocks the high temp trip
Block is removed 15 secs after power is restored
What is the flow set at for the SCW Deionizer and why?
100 gpm
prevent channeling
What is used to purge air out of the generator?
CO2
What forces flow to generator condition monitor?
DP produced by the fans attached to the generator rotor
When will GSO-251 close and why?
50# and lowering
to prevent H2 leak into turbine building
What are the U1 seal oil supplies in order? with Pressures.
MSOP 130#
Emergency SOP 125#
Shaft Driven Oil pump 120#
Bearing Oil Hdr 25#
What is the purpose of the seal oil recirc pump?
retard foaming and aid in degassing
What will trip the U2 Seal Oil Vac Oil Pump?
Lo vac oil tank level
What will trip the U2 Seal Oil Vac Pump?
Hi vac oil tank level
What is the purpose of 2-LRV-608 air oil pressure reg valve?
keeps air oil pressure 7# greater than generator gas pressure
How much higher in pressure is Vac oil and H2 oil pressure than air oil?
6# greater
When does the U1 turning gear engage?
When the turbine stops
What is the U1 #2 stop valve used for?
chest warming
Which oil pump will be running in U1 immediately after a Turbine Trip?
All except bearing lift pumps
Why would the U2 knife switches be opened when the reactor is tripped?
prevent overspeed to allow the turbine to stay on grid
Why do reheat stop and intercept valves close on a main turbine trip?
Prevent overspeed
What is the purpose of the Main Turbine Thurst Bearing?
Prevents stationary and rotating blade contact
When does the U2 main turbine go on it’s turning gear?
when turbine speed is <40 RPM
What supplies U2 Steam seals to the HP Turbine inner seals?
Main Steam
How much higher are HP Turbine inner steam seals than HP Turbine exhaust?
10#
What supplies U2 steam seals at low power, startup and shutdown?
Aux Steam