What is the tech spec minimum of the CST?
182,000gal
What are the HWP auto starts?
Low # at:
130# (U1)
110# (U2)
What are the HWP trips?
Overload/Overcurrent
What powers the HWPs?
4kV RCP Buses
1/2D North
1/2A Middle
1/2C South
What are the CBP auto starts?
Low pressure at 325#
What are the CBP trips?
Overload/Overcurrent
What is the flow capacity of the LP #1 heaters?
Each string supplies 50% flow (We have 3)
What is the flow capacity of the LP #2-4 heaters?
Each string supplies 80% flow (we have 2 strings) with a bypass that can provide 20% flow via CRV-224
What does CRV-55 do for you?
Allows makeup from the CST to the Condenser Hotwells (Sensed on A and C hotwell lvl)
What does CRV-155 do for you?
Allows for excess condensate from hotwells to go back to the CST (Sensed on A and C hotwell lvl)
What does CRV-224 (2,3,4 Heater bypass valve) do?
- Allows having a heater string out and provides 20% flow
- Auto modulates open when MFP suction < 240#
- Trips open at 210# MFP Suction
How do you reset CRV-224 (2,3,4 Heater bypass valve)?
Run controller to open when MFP Suction pressure > 260#
What do CRV-201, 202 and 203 (Condensate Booster Pump Recirc Valves) do?
Maintain 4000 gpm on running pumps
Where is the flow switch located for the Condensate Booster Pump Recirc Valves?
Flow switch is on the common discharge header
What do CMO-101(102) (SJAE bypass valves) allow?
- Manually position to achieve desired DP across SJAEs
- Prevents exceeding design flow of SJAEs
How much hood spray does each unit have?
- 138gpm (U1)
- 1200gpm (U2)
What does CMO-61 (SJAE and HWP recirc line valve) do for you?
- Provides continuous flow path from steam jet air ejector header to the main condensers to maintain minimum flow through the hotwell pumps and steam jet air ejector condensers
- 2400gpm min per pump
What does the basis for T.S. 3.7.6 (CST) state
To remove heat from 100% to no-load MODE 3 and to either remove decay heat for 2 hours in M3 then cool down to RHR assuming loss of offsite power. OR to remove decay heat for 9 hours in M3 assuming loss of offsite power as the initiating event.
≥ 138,335 usable gallons, which is based on the more limiting of either holding the unit in MODE 3 for 9 hours or holding the unit in MODE 3 for 2 hours followed by a 4 hour cooldown to RHR entry conditions
What suction pressure do the CRV-224 valves help to maintain?
210 psi - 240 psi MFP Suction Pressure
- Begins modulating at 240 psi
- Trips open at 210 psi
What Unit(s) have Condenser equalizations and what are they for?
Unit 1 to maintain even stresses (by temperature and pressure) on the Turbine Bearings
Explain the purpose and functions of the Condensate Chemical Feed System.
Minimizes secondary side piping and steam generator corrosion by injecting chemicals that control pH and scavenge residual dissolved oxygen.
What actuates hood spray in Unit 1 (CRV-102) and Unit 2(CMO-40)?
- Generator Load < 7.5% and Turbine Speed > 900 rpm
- Manual
If ‘A’ Hotwell is providing input to the HW Lvl Ctlr, then which hotwell level is being displayed on the Chart Recorder?
‘C’ Hotwell level is being displayed on the chart recorder
How does CRV-55 fail?
Closed
How does CRV-155 fail?
Closed
At what Generator Load OR Turbine Speed does Hood Spray Terminate for both units?
Generator load is > 12.5% OR Turbine speed is < 900 rpm