Foam Operations (pt 2) Flashcards
What are the steps to fill the class A tank into the Huskey 3?
- Place in pump.
- keep the foam pump off
- Throw the foam supply lever to draft.
- Throw the foam selector valve behind pump panel to “fill”
- Hit the decrease button until it says “fil”
- Turn on
- Return levers to “tank” and “foam”
What do I do if I lose prime when drafting on Huskey 3?
- First push and hold the prime button.
2. If that doesn’t do anything then open the foam pump discharge drain as a second step
All foam capable discharges have to go through foam manifold where the foam is actually injected; this keeps the foam out of the general circulation; But the foam manifold can only flow about how much gpm?
750gpm (two 1 ¾ and one 2 ½)
What do I do before connecting the pickup tube?
open the foam pump intake drain to remove some pressure
To fill Class A tank, I must be in …
pump mode
The Prime Mode is used to…
- accelerate the foam pump for a short period of time,
- such as to purge the air out of the on-board tank lines after initial filling
- Recharge system
- or to fill the suction hose while drafting.
For Huskey 10s and 12s what are the steps for drafting class B / F500 foam?
- Flow water
- Relieve pressure in foam intake drain
- Connect pickup tube and place in foam
- Page over to draft class B and hit enter