Fires Involving Chimneys And Ducting Flashcards
Consider early use of what?
Incidents - chimney/ducting
Aerial appliances
Hazards when attending fires involving chimneys or ducting?
Working at height Falling debris Explosion Heavy fire loading Unexpected fire or smoke spread Hearth fires Insulating materials Electrical extraction systems or filters Damage control Unauthorised building works
IC must make every effort to obtain building plans to assist with tracking the route of ducting as consider requesting who, to assist with interpretation of these?
Fire safety officer
What are fire dampers?
Automatic fire prevention systems used in heating, ventilation and air con ducts designed to prevent the spread of fire inside the ductwork through fire resistant walls and floors.
Where ducting systems have electrical powered electrostatic filters or extractors the IC must ensure what?
They have been isolated if water is going to be used as the extinguishing media.
Use of elec gloves to be considered.
Where possible would you extinguish ducting/chimney fires from the base or top?
Base