Fire Detection Flashcards
Detectors
5 digital sensors (2 each eng, 1 APU)
- -3 on firewalls
- -2 (eng only) deck mounted
Trigger T-Handle when detect infrared radiation and no blue light (sunlight)
Sunlight filtered through smoke or haze or at sunrise/sunset may trigger detectors
Extinguishers
Provide two-shot capability (main and reserve) to either engine compartment or APU compartment
2 bottles filled with halon, charged by nitrogen
Engine T-Handle Operation
Engine handle pulled aft arms the system and mechanically places the fuel selector in the OFF position
Logic module determines which CADS to fire and into which compartment
When both #1 and APU handles pulled, extinguishes last compartment pulled
If #2 pulled, always aims that compartment
APU T-Handle
Removes electrical power from the APU airframe fuel shutoff valve, allowing it to close
Also removes electrical power from the prime boost pump, sends a stop signal to the ESU/DESU, arms fire extinguisher system and positions valve to APU compartment
Notes
- If No 2 DC PRI bus not energized (no ac power), the RESERVE position must be used to discharge the agent into the APU or No 1 engine compartment (No 2 will have no extinguisher capability without ac power)
- When ac power is available, activation of multiple T-handles may result in both bottles being fired at the same time, leaving no reserve capability
Impact Operation
10g sensor mounted to airframe activated via power from BATT UTIL bus, discharging one bottle to each engine compartment