DETERMINATION OF WEAK D Flashcards
1
Q
Weak D expression can be recognized most reliably by an
A
indirect anti-human globulin test (IAT)
2
Q
Normal Saline Solution (__ NaCl)
A
0.85%-0.9%
3
Q
negative reaction should be further tested for the presence of weak D with the use of AHG
A
Rh negative initial
4
Q
the blood that results without agglutination after mixing its 5% rcs to an anti D is reported as
A
Rh negative initial
5
Q
how to validate if the negative AHG result
A
use coomb’s check cells
6
Q
composition of coomb’s check cells
A
group O cells synthesized with IgG
7
Q
INVALID coomb’s check cells
A
without agglutination
8
Q
INVALID coomb’s check cells resolution
A
9
Q
A