Chapter 13 Flashcards

Master stream application

1
Q

The most important question and infinite commander must ask is

A

At what point does this building no longer have any value when the life safety priority has been addressed and there’s no suitable property to protect the primary mission is over it’s time to put the fire out with a master stream

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is a large caliber device used primarily during defensive strategy operations they are also known as heavy stream and large caliber stream devices

A

Master stream

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Master Stream appliances are also used in ‘’’ attacks

A

Transitional

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the two types of master stream transitional attacks? Which one is riskier ?

A

Offensive- defensive - risker
Defensive- offensive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What ATTACK is an example of a pre-plumbed monitor that is defense to offensive transitional attack regarding master stream transitional attacks

A

Blitz attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What should be one of the safest fires we fight?

A

Defensive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What zone is an area endangered by potential wall collapse of a building it is calculated by the distance out of the wall ‘’ the height of the involved building

A

Collapse zone, 1.5 times the height

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Master stream appliances should be As far away from the fire as possible without compromising their ‘’

A

effectiveness p. 421

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

There are essentially how many types of master stream appliances… What are they?

A

3
Two are carried on engine ( fixed and portable )
1 on aerial ladder

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Portable mass appliances are often referred to as x4

A

deluges
Monitors
Deck guns
Ladder pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The safety lock is provided so that the lock must be manually release before the barrel can be lowered below ‘’ angle

A

35° p. 424

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Water supplied to the ‘’ appliance in one of two ways, which are:
1- pre-plumbed to the appliance from a separate discharge gate on the pump
2 - supplied by hose lines with one or more connections to the pumpers discharge our. Can be monitors on trucks.( monitors.)

A

fixed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Depending on the size carried on the monitor, it can flow between ‘’’ gpm, which gives only between’’’ seconds of water

A

500 to 1000 gallons per minute
30 to 60 seconds of water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Elevated platforms of’’’ ft or less rated vertical height must have a permanent water delivery system installed capable of delivering ‘’’ gallons per ‘’’ psi nozzle pressure with elevating platforms at its rated vertical height

A

110 feet
Thousand gallons per minute at 100 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Permanent waterways on both aerial ladders and elevating platforms must be arranged so that they can supply at ground level through an external intake. That is a minimum of ‘’ inches

A

4 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Various sizes of smooth board tips are available for use with master stream app appliances. The most common are.

A

1 1/4 - 400 gpm
1 3/8 - 500 gpm
1 1/2 - 600
1 3/4 - 800
2 inch - 1000
Usually operate at nozzle pressures of 80 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

If Water supply is a problem regarding master streams what must be used?

A

A smaller tip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

1 1/4 inch tip is often furnished as part of

A

A ladder pipes assortment of smooth board tips

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Combination master stream nozzles are available many sizes their designed to operate at ‘’’ psi with water delivery rage, generally up from the ‘’

A

Hundred PSI
300 to 1250 GPM p. 427

20
Q

Some combinations spray nozzles are constructed so that the flow rates can be buried generally in increments of

A

250
350
500
750
1000 GPM

21
Q

Master stream appliance is only as good as

A

It’s water supply p. 428

22
Q

Never lay forward from a hydrant ‘’’ unless another engine is hooked up to the hydrant

A

To the Aerial ladder for ladder pipe operations

23
Q

COMBO Spray nozzle should be used to cover ‘’ : bore tips are better suited for?

A

Exposure fires
Firefighting

24
Q

What has proven to be the most effective for fire attack when using a master stream appliance REGARDING NOZZLE

A

The solid stream from a smooth bore tip, penetrates farther into the building, covering more of the fire while delivering more GPM and is least affected by the wind

25
What nozzle using a straight stream even from a master stream appliances loses its effectiveness if it must be applied over any distance
Comb spray nozzle using a straight stream
26
If there's any question about ability of a straight stream to reach a fire or exposure or windy conditions, what should be used?
Solid stream from a smooth bore p. 432
27
On average aerial ladder, pipes and tower ladder, master streams are effective up to what floor
12th floor
28
To be most effective and fire control, and master stream should be moved
Horizontally back-and-forth across the Fire area it is covering Up and down/side to side
29
How to tell if the master stream is entering the building: use a ''' listen for '' look for '' theses are all signs the stream isnt entering the building..
use a Tic Listen for the sound of the stream hitting the building And you should look for heavy water runoff both signs indicate the stream is not entering the building p. 435
30
Direct water on the exposure is more effective than Directing a stream between the fire and the exposure, unless a '' is specifically set up to extinguish flying embers as in large lumberyard fires.
water curtain
31
''' stream is most effective when using an elevated stream appliance
Solid stream
32
For exposure protection nozzle, using a '' nozzle may be superior to a solid stream if it is not affected by the wind or distance from the fire
fog stream Combination
33
Elevated master streams, especially fog streams, must never be
Directed into naturally exhaust openings such as skylights scuttles and hatches , holes made in the roof for venting the smoke or whatever the fires already burned through the roof p. 437
34
Firefighters vent roof to allow what to escape the building so that interior attacks can be carried out
Smoke heat, and gases
35
Vertical ventilation allows FF to perform a '', get to the seat of the fire and ''
Primary search Apply water to extinguish the fire
36
The mistake of directing elevated mass streams into an opening or vent is essentially placing a lid over the ventilation exhaust, prevent the heat and gases from escaping it causes the ventilation flow path to
Reverse itself and seek other least resistance in order to vent p-. 437
37
The interior warning signs for '' include: Spongy roof and sagging roof deck Sagging floors or fire burning from the floors Ceiling dropping Structural movement of floors, bearing wall, beams, and columns Loud noises
collapse
38
Examples of '' warning, signs of building collapse: Fires burning out of control longer than 20 minutes without progress No water runoff from stairways and doors Cracks in the walls Water and smoke pushing from cracks Separation of the roof from the walls Visible on every floor. 439
exterior
39
What is an alternative method to fire scene tape when marking off the collapse zone?
Uncharged fire line
40
Up to what water flow can master stream appliances require
2000 GPM
41
How long can you supply water from the tank on the engine when using a fixed master stream appliance during a blitz attack?
30 -60 SECS
42
At what pressure do smooth-bore tips on master stream appliances operate? PSI
80 PSI
43
Which type of attack is used when there is more fire than 1 3/4-inch and 2 1/2-inch hand lines can handle, but the building still has value and is savable? WHAT ATTACK IS AN EXAMPLE ?
Defensive to offensive transitional attack Blitz attack
44
What happens when water is delivered to the master stream nozzles at an insufficient rate
Stream breaks up 427
45
What is the smallest tip used on master stream appliances? p. 427
1 1/4
46
What part of the fire must the master stream reach to be effective in extinguishing the fire? p. 434
base
47
Where is it best to position elevated master stream appliances when operating in a defensive mode to achieve effective streams? p. 437
AT THE CORNERS