Chapter 13 Flashcards
Master stream application
The most important question and infinite commander must ask is
At what point does this building no longer have any value when the life safety priority has been addressed and there’s no suitable property to protect the primary mission is over it’s time to put the fire out with a master stream
What is a large caliber device used primarily during defensive strategy operations they are also known as heavy stream and large caliber stream devices
Master stream
Master Stream appliances are also used in ‘’’ attacks
Transitional
What are the two types of master stream transitional attacks? Which one is riskier ?
Offensive- defensive - risker
Defensive- offensive
What ATTACK is an example of a pre-plumbed monitor that is defense to offensive transitional attack regarding master stream transitional attacks
Blitz attack
What should be one of the safest fires we fight?
Defensive
What zone is an area endangered by potential wall collapse of a building it is calculated by the distance out of the wall ‘’ the height of the involved building
Collapse zone, 1.5 times the height
Master stream appliances should be As far away from the fire as possible without compromising their ‘’
effectiveness p. 421
There are essentially how many types of master stream appliances… What are they?
3
Two are carried on engine ( fixed and portable )
1 on aerial ladder
Portable mass appliances are often referred to as x4
deluges
Monitors
Deck guns
Ladder pipe
The safety lock is provided so that the lock must be manually release before the barrel can be lowered below ‘’ angle
35° p. 424
Water supplied to the ‘’ appliance in one of two ways, which are:
1- pre-plumbed to the appliance from a separate discharge gate on the pump
2 - supplied by hose lines with one or more connections to the pumpers discharge our. Can be monitors on trucks.( monitors.)
fixed
Depending on the size carried on the monitor, it can flow between ‘’’ gpm, which gives only between’’’ seconds of water
500 to 1000 gallons per minute
30 to 60 seconds of water
Elevated platforms of’’’ ft or less rated vertical height must have a permanent water delivery system installed capable of delivering ‘’’ gallons per ‘’’ psi nozzle pressure with elevating platforms at its rated vertical height
110 feet
Thousand gallons per minute at 100 psi
Permanent waterways on both aerial ladders and elevating platforms must be arranged so that they can supply at ground level through an external intake. That is a minimum of ‘’ inches
4 inches
Various sizes of smooth board tips are available for use with master stream app appliances. The most common are.
1 1/4 - 400 gpm
1 3/8 - 500 gpm
1 1/2 - 600
1 3/4 - 800
2 inch - 1000
Usually operate at nozzle pressures of 80 PSI
If Water supply is a problem regarding master streams what must be used?
A smaller tip
1 1/4 inch tip is often furnished as part of
A ladder pipes assortment of smooth board tips
Combination master stream nozzles are available many sizes their designed to operate at ‘’’ psi with water delivery rage, generally up from the ‘’
Hundred PSI
300 to 1250 GPM p. 427
Some combinations spray nozzles are constructed so that the flow rates can be buried generally in increments of
250
350
500
750
1000 GPM
Master stream appliance is only as good as
It’s water supply p. 428
Never lay forward from a hydrant ‘’’ unless another engine is hooked up to the hydrant
To the Aerial ladder for ladder pipe operations
COMBO Spray nozzle should be used to cover ‘’ : bore tips are better suited for?
Exposure fires
Firefighting
What has proven to be the most effective for fire attack when using a master stream appliance REGARDING NOZZLE
The solid stream from a smooth bore tip, penetrates farther into the building, covering more of the fire while delivering more GPM and is least affected by the wind