What is the required minimum lot area of single-detached houses for socialized housing subdivisions?
64 sqm
What is the required minimum lot area of duplex and single attached houses for socialized housing subdivisions?
48 sqm
What is the required minimum lot area of rowhouses for socialized housing subdivision?
32 sqm
What is the required minimum lot frontage of a single-detached house in a corner lot?
8 meters
What is the required minimum lot frontage of single-detached houses in regular lots for both socialized and economic housing development?
8 meters
What is the required minimum lot frontage of single-detached houses in irregular lots for both socialized and economic housing development?
4 meters
Subdivision projects abutting the main public thoroughfare must provide minimum setbacks at least how many meters in its depth and length?
3 meters in depth by 5 meters in length
What is the required distance of street lighting per pole?
50 meters
What is the required minimum lot frontage of single-detached houses in interior lots for both socialized and economic housing development?
3 meters
What is the required minimum lot frontage of duplex or single attached house for both socialized and economic housing development?
6 meters
What is the required minimum lot frontage of row houses for both socialized and economic housing development?
4 meters
Firewalls shall have a minimum fire resistance of how many hours?
1-hour fire-resistive rating
The minimum headroom clearance in ceiling height
2 meters
The minimum clear ceiling height of mezzanines
1.80 meters
The maximum length of blocks for both socialized and economic housing developments
400 meters
Rooms for habitable use shall be provided with windows with a total free area of openings equal to at least?
10% of the floor area of the room
Bathrooms shall be provided with a window(s) with an area not less than?
1/20 of its floor area
Stairways shall have a minimum clear width of?
600 mm
The maximum stair riser height and minimum tread length of stairs
250 mm riser (max.)
200 mm tread (min.)
The required length of blocks that shall be automatically provided with a two (2) meter wide alley approximately at its mid-length
250 meters
The required minimum clearance of handrails from walls to which they are fastened
38 mm
The required minimum headroom clearance for stairs
2 meters
The required maximum number of residential units for rowhouses per block or cluster but in no case be more than 100 meters in length
20 units per block or cluster
The minimum floor area of single-family dwelling for economic housing projects
22 meters
The required minimum floor area of single-family dwelling for socialized housing projects
18 sqm
The minimum height and thickness of firewalls extending vertically from the lowest portion of the wall adjoining the living units
300 mm, 100 mm
The required minimum front setback of dwelling units for both economic and socialized housing projects
1.50 meters
The minimum horizontal clearance between two roof eaves
1.50 meters
The required minimum side yard setback of dwelling units for both economic and socialized housing projects
1.50 meters from the building line
The four (4) site criteria for subdivision development
- Availability of basic needs
- Conformity with the zoning ordinance or land use plan of the city/municipality
- Physical suitability
- Accessibility
The four (4) factors involved in site considerations for subdivision development
- Area planning
- Site preservation/alteration
- Easements
- Circulation
Three (e) elements of site preservation/alteration in subdivision planning
- Slope
- Site preservation of assets
- Ground cover
The open spaces in subdivisions comprising those allotted for circulation systems, community facilities, parks, and playgrounds
Non-saleable areas
The required allocated percentage of gross area for parks and playgrounds for economic and socialized housing developments having a density of 151-160 dwelling units per hectare
4%
The required allocated percentage of gross area for parks and playgrounds for economic and socialized housing developments having a density of 201-225 dwelling units per hectare
7%
The required allocated percentage of gross area for parks and playgrounds for economic and socialized housing developments having a density of 176-200 dwelling units per hectare
6%
The required minimum thickness of asphalt if it is to be applied for major, minor roads, and motor courts for economic and socialized housing projects
50 mm
The required minimum thickness of concrete if it is to be applied for major, minor roads, and motor courts for economic and socialized housing projects
150 mm
The required finish for sidewalks and alleys
Macadam
The minimum distance between road offset intersections
20 meters from corner to corner
The required minimum slopes of crowns of the roads
1.5% to 9%
The required maximum length of path walk intended only as pedestrian access to the property for socialized housing projects
60 meters
The required minimum lot area of single-detached houses for an economic housing subdivision
72 sqm
The required minimum lot area of duplex and single attached houses for an economic housing subdivision
54 sqm
The required minimum lot area of rowhouses for an economic housing subdivision
36 sqm