RA 9514 new stairs minimum width clearance for < 5 occupants
0.915 m
RA 9514 new stairs minimum width clearance for < 2000 persons
1.12 m
RA 9514 new stairs minimum width clearance for > 2000 persons
1.42 m
RA 9514 new stairs maximum height of risers
0.18 m
RA 9514 new stairs minimum height of risers
0.10 m
RA 9514 new stairs minimum width of run (exclusive of nosing)
0.28 m
RA 9514 new stairs maximum width of nosing
5 mm
RA 9514 new stairs maximum height between landings
3.66 m
RA 9514 new stairs minimum headroom clearance for stairs
2 m
RA 9514 existing stairs minimum width clearance
0.915 m
RA 9514 existing stairs maximum height of risers
0.205 m
RA 9514 existing stairs minimum height of risers
-
RA 9514 existing stairs minimum width of run (exclusive of nosing)
0.23 m
RA 9514 existing stairs maximum width of nosing
-
RA 9514 existing stairs maximum height bet. landings
3.66 m
RA 9514 existing stairs minimum headroom clearance for stairs
2 m
BP 220 minimum width clearance
0.60 m
BP 220 maximum height of risers
0.25 m
BP 220 minimum height of risers
-
BP 220 minimum width of run (exclusive of nosing)
0.20 m
BP 220 maximum width of nosing
-
BP 220 maximum height of landings
3.60 m
BP 220 maximum width between landings
-
BP 220 minimum headroom clearance for stairs
2 m
PD 1096 minimum height of handrail at stairways
800 mm - 900 mm
PD 1096. Stairways 1.10 m or less in width and stairways serving one individual dwelling unit in Group A or Group B occupancies may have _____ handrail
1
Stairways having less than four risers
Need not have handrails
RA 9514 minimum height of handrail at stairways
760 mm - 865 mm (measured from 25 mm from the surface of the tread)
BP 344 minimum height of handrail at stairways
900 mm
BP 220 minimum height of handrail at stairways
Min. 800 mm - 1.20 m
Foundations may be permitted to encroach into public sidewalk areas to a width not exceeding _____, if
- Top of the foundation ≥ 600 mm below the established grade
- Projections does not obstruct any existing utility
500 mm
Footing encroachment fronting a national highway
300 mm
Footing encroachment fronting other roads
500 mm
Arcade clearance height from the sidewalk
3 meters
Awning encroachment
2.4 meters
Awning clearance height from the sidewalk upon encroachment
3 meters
Min. chamfer
4 meters
The allowable projection for the signage of a building that is not arcaded
1.20 m, 3 meters clear distance
The allowable projection for the signage of a building that is arcaded
1 m, 5 meters clear distance
Footbridge
1.27 m clear
Perpendicular or diagonal parking slot dimensions
2.50w x 5.00d
Parallel parking slot dimensions
2.15w x 6.00d
Truck or bus parking slot dimensions
3.60w x 12.00d
Container van, bulk carrier, prime move, articulated truck parking slot dimensions
3.60w x 18.00d
Jeepney, shuttle parking slot dimensions
3.00w x 9.00d
Liquids having flashpoints below 37.8 °C
Flammable liquids
The minimum temperature at which any material gives off vapor in sufficient concentration to form an ignitable mixture with air
Flashpoint
153 mm diameter where the highest outlet is higher than 23 m above the service connection
Dry standpipe
HIGC
Home Insurance Guarantee Corp.