Atlas Building Laws 2 Flashcards
BP 220 firewall min. vertical extension
300 mm above the apex of the roof
BP 220 firewall min. horizontal extension
300 mm beyond the outermost edge of the abutting living units
BP 220 minimum fire-resistive hour rating
1-hr min. fire-resistive rating
BP 220 maximum units per block (rowhouse)
20 units of not more than 100 meters in length
Minimum lot area of rowhouse for open market housing
60 sqm
Minimum lot area of rowhouse for medium-cost housing
50 sqm
Minimum lot area of rowhouse for economic housing
36 sqm
Minimum lot area of rowhouse for socialized housing
28 sqm
Minimum lot area of duplex for open market housing
96 sqm
Minimum lot area of duplex for medium-cost housing
80 sqm
Minimum lot area of duplex for economic housing
54 sqm
Minimum lot area of duplex for socialized housing
48 sqm
Minimum lot area of single-detached for open market housing
120 sqm
Minimum lot area of single-detached for medium-cost housing
100 sqm
Minimum lot area of single-detached for economic housing
72 sqm
Minimum lot area of single-detached for socialized housing
64 sqm
The minimum distance between 2 buildings of up to 2-story for multi-family dwelling
4 meters
The horizontal clearance between roof eaves
1.50 meters
The minimum area of the kitchen
3 sqm
The minimum area of the toilet
1.2 sqm