APU System Flashcards

1
Q

What kind of APU is on the aircraft?

A

Sundstrand APS 2300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Describe the APU

A
  • Constant speed
  • Single stage impeller with a 2 stage axial flow turbine
  • Independent oil system
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What controls the APU?

A

A dedicated FADEC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What battery is used for the APU start?

A
  • -Battery 2 powers the starter
  • -Battery 1 powers the FADEC and EICAS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the fuel source for the APU?

A
  • Right Fuel Tank
  • Left fuel tank through the cross feed valve
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What fuel pump is used for APU start

A
  • With Batteries only - DC fuel pump in right tank
  • With AC power available - ACMP 2
  • Right engine running ejector fuel pump
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Will the APU shutdown automatically if speed and acceleration

rate isn’t reached in starting cycle time?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does moving the APU start switch to “OFF” do?

A
  • Initiates normal shutdown
  • 1 minute cool down
  • No Pneumatics (electrics only for 1 minute)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Can the APU shutdown be canceled?

A

Yes

By moving the start switch back to”ON”

before the 1 minute cool down is over

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How do you shut down the APU immediately?

A
  • APU “Emergency stop button”
  • No 1 minute cool down period
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What will happen if batteries are turned

off during the 1 minute cool down period?

A

APU will shut down immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When will automatic shutdown occur on the Ground?

A

FOUL FO

  • FADEC critical fault
  • Overspeed
  • Underspeed
  • Low oil pressure
  • Fire
  • Overheat
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When will automatic shutdown occur in Flight?

A
  • Overspeed
  • Underspeed
  • FADEC critical fault
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Can the APU be started after a critical fault?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Maximum Start Altitude?

A

30,000’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Maximum EGT Start

A

1032c

17
Q

Max Rotor Speed

A

108%

18
Q

Max Continuous EGT

A

717c

19
Q

Max Operating Altitude

A

33,000’

20
Q

Max Generator Altitude

A

33,000’

21
Q

Starter Duty Cycles

A

1 minute on

1 minute off

1 minute on

1 minute off

1 minute on

5 minutes off

22
Q

Maximum Bleed Altitude

A

15,000’