APU Flashcards

1
Q

Voltaggio e Amperaggio erogato dall’APU

A

115 V 40KVA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Cosa succede quando si preme APU EMERGENCY STOP?

A

It closes fuel shutoff valve without cooling period.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Describe APU fuel supply

A

When only DC, from the DC fuel pump (right tank).
When AC but with no engine running, from AC fuel pump (right tank)
When engine is running, fuel will be provided via the ejector fuel pump.
It is also possible to provide fuel via crossfeed from left tank.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many second is better to wait after EICAS is energized, to start the APU? To avoid unsuccessful start.

A

30”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When is electrical and pneumatic available?

A

3” after APU speed has reached 95%.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Cosa succede in un normale shutdown?

A

Pneumatic power is immediately removed;
electrical power is removed after at the end of a 1’ cooldown, which is followed by a spool down period, at the END of the spooldown period the message APU SHUTTING DOWN disappears.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In which cases FADEC provides automatic shutdown ON GROUND?

A

Overspeed, Underspeed, Fire, EGT overtemp, high oil temp, low oil pressure, sensor fail, FADEC critical fault.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

In which cases FADEC provides automatic shutdown ON GROUND?

A

Overspeed, Underspeed, Fadec Critical Fault

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Apu starter limits, cool period after each attempt:

A

1st 2nd attempt, 60” OFF
3rd 5’ OFF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly